Oncotarget

Research Papers:

Analysis of the variability among radiation oncologists in delineation of the postsurgical tumor bed based on 4D-CT

PDF |  HTML  |  How to cite

Oncotarget. 2016; 7:70516-70523. https://doi.org/10.18632/oncotarget.12044

Metrics: PDF 1411 views  |   HTML 1724 views  |   ?  

Wei Wang, Jianbin Li _, Jun Xing, Min Xu, Qian Shao, Tingyong Fan, Bing Guo and Shanshan Liu

Abstract

Wei Wang1, Jianbin Li1, Jun Xing1, Min Xu1, Qian Shao1, Tingyong Fan1, Bing Guo1, Shanshan Liu1

1Department of Radiation Oncology, Shandong Cancer Hospital affiliated to Shandong University, Shandong Academy of Medical Sciences, Jinan, Shandong province, China, 250117

Correspondence to:

Jianbin Li, email: [email protected]

Keywords: breast-conserving treatment, tumor bed delineation, surgical clip number, CT slice thickness, cavity visualization score

Received: March 09, 2016     Accepted: August 24, 2016     Published: September 15, 2016

ABSTRACT

Objective: This study investigated interobserver and intraobserver variability in radiation oncologists’ definition of the tumor bed (TB) after breast-conserving surgery (BCS).

Results: The TB volume, CVS and number of surgical clips were not significantly related to intraobserver variability. Moreover, no correlation was noted between CT slice thickness and interobserver variability (Δinter, DSCinter) in TB delineation, and no significant difference was noted among the three groups. The TB volume was negatively correlated with Δinter. DSCinter improved significantly with increased TB volume and decreased Δinter. DSCinter also increased significantly in patients with a CVS of 3 to 5 compared with patients with a CVS of 1 to 2. DSCinter was thus positively correlated with the CVS, with a correlation coefficient of 0.451. The use of 7 to 9 surgical clips neither decreased Δinter nor increased DSCinter.

Materials and Methods: Five or more surgical clips were placed at the TB during lumpectomy. The TB was delineated on the end expiration scan. The data were stratified based on the cavity visualization score (CVS), CT slice thickness and surgical clip number. The Dice similarity coefficient (DSC) and inter(intra)observer variability (Δinter and Δintra) in different groups were evaluated and compared.

Conclusions: Inter(intra)observer variability in TB delineation was decreased for breast cancer patients implanted with 5 or more surgical clips in the cohort with a higher CVS and a larger TB. The use of more than 6 surgical clips did not significantly improve TB delineation, so 5 to 6 surgical clips are likely adequate to delineate the TB.


INTRODUCTION

Developments in radiation therapy delivery after breast-conserving surgery (BCS), such as three-dimensional conformal external beam radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and image-guided radiation therapy (IGRT), have improved the accuracy of radiation delivery [1-3]. Whole-breast irradiation (WBI) with or without a tumor bed (TB) boost in combination with BCS remains the standard treatment for early-stage breast cancer. However, external beam partial breast irradiation (EB-PBI) has recently attracted more attention in this field [4-6]. Several issues and unanswered questions remain regarding the use of EB-PBI or WBI with a TB boost after BCS, including inter-fraction breathing motion and intra-fraction set-up variation, which may lead to displacement and deformation of the planning target volume (PTV). Definite delineation and contouring of the TB are also crucially important. Many factors influence TB identification, such as the cavity visualization score (CVS) on computed tomography (CT), the interval from BCS to the CT simulation scan, the number of surgical clips placed during surgery, and breast distortion after surgery [5-9].

Accurate localization and delineation of the TB are most critical in patients undergoing WBI with a TB boost and EB-PBI. However, the definition of the TB volume after BCS is controversial [7, 8, 10-13], and no consensus is available regarding the first-choice modality for TB contouring. Three-dimensional CT (3D-CT) is broadly applied in radiotherapy simulation, and the TB is delineated on 3D-CT images. However, 3D-CT does not avoid the effects of breathing motion on the accuracy of target volume delineation. The image-guided deep inspiration breath hold (DIBH) treatment protocol is a feasible irradiation method with small setup variability that significantly reduces the dose to the heart [14-16]. However, the accuracy of active breathing control (ABC) is altered by pulmonary function and the threshold of inspiration capacity that is chosen to perform DIBH. Four-dimensional CT (4D-CT) has also been evaluated in a few planning studies for breast cancer radiotherapy simulation, and it significantly reduces the target delineation errors caused by motion artifacts [17-19].

Additionally, recent studies demonstrated that 4D-CT-based target delineation was more accurate for WBI and EB-PBI [20, 21]. Delineation standard setting, delineation training, the CVS, and the number of surgical clips are all very important for the accuracy of TB delineation [7, 22-24]. In particular, recent studies suggested that the placement of 4 to 6 surgical clips may improve the accuracy of target structure delineation [5, 11, 25]. However, whether further increases in the number of surgical clips within the TB will improve the accuracy of EB-PBI with a TB boost following or concurrent with WBI delivery is not known. The effects of different CT slice thicknesses, the TB volume, and the CVS on the concordance among radiation oncologists in TB determination when 5 or more surgical clips are placed at the TB are also not clear. Here, by evaluating the relationship between the number of clips and seroma-based TB delineation on postoperative 4D-CT scans for EB-PBI and boost following or concurrent with WBI delivery, we investigated whether the presence of more surgical clips would improve interobserver and intraobserver variability in radiation oncologists’ accuracy in TB delineation.

RESULTS

Patients and treatment

A total of 66 patients with SIB or EB-PBI were enrolled in this study. Seventeen patients refused undergo 4D-CT simulation, fourteen patients were excluded because they were receiving neoadjuvant chemotherapy for a tumor larger than 5 cm. Therefore, 35 early-stage breast cancer patients who had undergone BCS were eligible. Table 1 outlines the patient characteristics. The mean patient age was 43.0 years (range 21 to 60 years). Eighteen of the 35 patients had right-sided breast cancer, and the remaining 17 patients had left-sided breast cancer.

Table 1: Clinical and TB characteristics of 35 patients

Variable

Value

Mean age (y)

43.0

 Minimum

21

 Maximum

60

T stage

 

 Tis

9

 T1

19

 T2

7

Histology

 

 DCIS

9

 IDC

21

 Other

5

Tumor location

 

 Left-sided

17

 Right-sided

18

TB size (cm3)

25.2 ± 15.0

 Range

4.59-79.3

CVS

2.51 ± 1.50

 CVS-1

13

 CVS-2

7

 CVS-3

4

 CVS-4

6

 CVS-5

5

No. of clips

6.31 ± 1.23

 5

12

 6

8

 7

9

 8

4

 9

2

Abbreviations: TB = tumor bed; CVS = cavity visualization score; DCIS = ductal carcinoma in situ; IDC = invasive ductal carcinoma.

Influence of CT slice thickness on TB delineation

The 4D-CT scans of the 35 patients with early breast cancer who had undergone BCS constituted the dataset for this retrospective study. The 4D-CT images for fourteen patients were reconstructed using a thickness of 2 mm, and 3-mm and 5-mm thicknesses were used for 14, 14 and 7 patients, respectively. Δintra, Δinter, DSCintra, and DSCinter for all patients were 7.78 ± 5.99%, 27.2 ± 25.5%, 87.0 ± 4.47% and 73.8 ± 9.31%, respectively. The patients were divided into three groups based on CT thickness. Statistical analyses demonstrated no significant differences in Δintra, Δinter, DSCintra, or DSCinter among the three groups (F = 0.472, 1.636, 0.799, and 0.322, respectively; P = 0.628, 0.211, 0.459, and 0.727, respectively). CT slice thickness thus did not influence Δintra, Δinter, DSCintra, or DSCinter (r = 0.161, 0.143, 0.207, and 0.093, respectively).

TB delineation analysis

We also investigated variations in TB definition using various factors that may influence TB delineation, including the TB volume, CVS, and presence of surgical clips (Table 2). The mean volume of the TB was 25.2 ± 15.0 cm3. The mean Δinter for the TB was reduced to 15.6%, from 37.0% (P = 0.009), and the mean DSCinter for the TB increased to 77.6%, from 70.6% (P = 0.025), with the increase in the TB volume. A significant inverse correlation was thus identified for the TB volume and interobserver variability in TB delineation.

Table 2: Factors influencing the delineation of the TB

Influencing factor

No. of patients

Δintra(%)

Δinter(%)

DSCintra(%)

DSCinter(%)

Vmean (cm3)

 

 

 

 

 

 <25.2

19

7.14

37.0

86.8

70.6

 ≥ 25.2

16

8.54

15.6

87.2

77.6

T

 

-0.664

2.796

-0.245

-2.343

 P

 

0.512

0.009

0.808

0.025

 Correction (r)

35

-0.019

-0.485

0.297

0.510

CVS

 

 

 

 

 

 1-2

20

7.96

32.2

86.3

70.1

 3-5

15

7.54

20.6

87.9

78.8

T

 

0.201

1.433

-0.141

-3.051

 P

 

0.842

0.161

0.305

0.004

 Correction (r)

35

-0.019

-0.117

0.168

0.451

No. of clips

 

 

 

 

 

 5-6

20

6.24

23.5

86.1

73.5

 7-9

15

9.83

32.2

88.2

74.2

T

 

-1.807

-0.948

-1.440

0.223

 P

 

0.080

0.353

0.159

0.825

 Correction (r)

35

0.305

0.082

0.193

0.052

Abbreviations: Vmean = TB volume; CVS = cavity visualization score.

The data were also stratified based on the CVS, and patients with a CVS of 1 to 2 or 3 to 5 were grouped using the guideline of Landis et al. [9]. There was no significant difference in the degree of agreement between radiation oncologists (P = 0.745). The higher CVS was recorded when a given patient received conflicting CVS values. The mean CVS assigned was 2.51 ± 1.50. Overall, the assignment of CVS values by each radiation oncologist was fairly consistent. DSCinter was significantly increased when the CVS was 3 to 5 compared with 1 to 2 (78.8% vs. 70.1%; P = 0.004) (Table 2). A positive correlation between the CVS and interobserver variability regarding TB delineation was thus identified.

At least 4 clips were placed at the radial extents of the cavity, and 1 clip was placed deeply [25]. When the breast tumor was anatomically deep, another clip was placed in front of the cavity. Twelve of the patients had five clips, 8 patients had six clips, 9 patients had seven clips, 4 patients had eight clips, and 2 patients had nine clips (Table 1). These patients were divided into two groups based on the surgical clip number (5 to 6 or 7 to 9). When at least 5 surgical clips were implanted in the TB, no significant differences were found in the interobserver or intraobserver delineation variability with increasing numbers of surgical clips. None of the relationship comparisons for TB volume variability and the clip number was significant (Table 2).

DISCUSSION

TB delineation is a critical factor for EB-PBI and breast boost radiotherapy. However, the ability to strongly visualize the TB depends on the breast tissue density; the optimal number of implanted TB surgical markers; the interval from surgery to radiotherapy; tissue stranding from the surgical cavity; the target volume delineation experience; and the pre-lumpectomy setting, such as magnetic resonance imaging (MRI) and 3D ultrasound (3D-US) [7, 8, 10-13, 23, 24]. Intraobserver variation was established for each variable in the present study.

The European Organisation for Research and Treatment of Cancer (EORTC) recommends the use of a 2- to 3-mm CT slice thickness because this slice thickness generates high-resolution digitally reconstructed radiographs, which facilitates accurate tumor delineation for the planning and delivery of high-dose, high-precision radiotherapy for lung cancer (grade of recommendation/description: 1B) [26]. Additionally, recent research has found that thin-slice 3D reconstruction images more clearly reveal the morphological characteristics of tumors and breast tissues and the margins of different tissues in each slice [27]. In the present study, variation of the reconstructed 4D-CT slice thickness did not produce inter(intra)observer variability among radiation oncologists in TB delineation in patients with early breast cancer who had undergone BCS. However, the tumor shapes that were obtained using the two reconstruction methods were basically similar after 3D reconstruction. Therefore, thin-slice images and differences in the reconstruction slice thickness of CT images did not improve the accuracy of surgical cavity delineation for patients with surgical clips that were placed during lumpectomy.

4D-CT provides information on the motion of mediastinal structures, which improves the delineation of target volume. Our prophase research has demonstrated that intrafraction target displacement during free breathing was limited, and the influence of intrafraction target displacement on the dose distribution is not significant during irradiation [19-21, 28-30]. However, no prior studies about translation of 4D-CT technical advances into clinical advantages, such as tumor control or survival, have been performed. Therefore, the integration of 4D-CT into the target delineation process was rational. A recent study by Cover et al. [31] found that the EE position of a tumor was maintained approximately 50% of the time and reduced the uncertainty in tumor location resulting from respiration. Therefore, all delineations were established at the EE phase in the present study. The ability to visualize the TB strongly depends on the breast tissue density [8]. Age, tumor size, the interval from surgery to radiotherapy, and the pathological resection volume are not related to breast density values. The present study assessed the correlation between both delineation variability and the DSC and the TB volume, and we found that the interobserver DSC for TB determination increased approximately 7% in women with a larger TB size and that the interobserver variability in delineation (Δinter) decreased from 37.0% to 15.6%. Landis et al. [9] recently demonstrated that the average shift in the center of mass was significantly smaller when the pathological diameter was > 4 cm using multiple linear regression. Therefore, in the current study, the TB boundaries for patients with a smaller TB exhibited low delineation concordance, despite the placement of surgical clips within the TB. CT imaging with MRI, 3D-US or PET/CT would benefit patients with a low-volume TB, which is associated with low simulation and TB delineation variability [13, 32, 33].

The TB volume constantly changes after surgery, and the CVS gradually declines. Therefore, a good grasp of the appropriate timing for simulation scanning is needed in this case. A lower Δinter or higher DSC value indicates better convergence among volumes and higher similarity among the compared contours. In the present study, patients with more than five surgical markers exhibited an improvement in TB delineation, with CVS scores of 3 to 5, and the interobserver variability in TB delineation was reduced by 11.7% (from 32.2% to 20.6%). Kader et al. [34] and Lewis et al. [35] suggested that the optimal time to obtain the planning CT scan for radiotherapy is within 8 to 9 weeks after surgery (and not more than 14 weeks afterward) to ensure that the seroma remain adequately defined in most patients. Given that the TB volume changes dramatically during this stage, combination of the CT-based seroma with surgical clips should provide a suitable guide for TB target volume definition. An inclusive delineation using the seroma and surgical clips should specifically be performed when a spatial mismatch exists among the TB volumes delineated based on the seroma and surgical clips.

The selection of the appropriate time from lumpectomy to CT simulation scanning and the use of a sufficient number of surgical clips must be considered to minimize errors in defining the TB [7, 8, 11, 25]. Clips implanted in surgical cavity walls provide additional localization information, but detachment or gathering of surgical clips appears over time after surgery and with increasing gradual mobility. Therefore, surgical clips do not completely represent the TB border. Many surgeons recommend the placement of 7 to 10 surgical markers at the time of surgery, although some prefer not to place clips. Ippolito et al. [5] investigated the percentage of intersection volume among clip-based clinical target volumes (CTVs) for PBI delineated on postoperative CT scans and the initial tumor location on preoperative CT scans and noted that surgical clips were essential and that the use of six or more clips led to inaccurate TB definition. However, pre- and postoperative CT image co-registration has limitations. First, limited soft tissue contrast on CT may make it difficult to visualize all breast tumors. Second, breasts are distorted after surgery. Interobserver variability was minimal for TB delineation based on seroma when the CVS was 3 to 5 points and when at least 5 surgical clips were placed during BCS in our preliminary experiments [28]. The present study demonstrated that the placement of more than 5 to 6 surgical clips at the time of lumpectomy did not improve the DSC, with less interobserver variability in TB delineation after BCS. However, a key limitation of our study was that it was only comparative, and we could not ensure the absolute error in determining the TB.

Our study should be interpreted while keeping two limitations in mind. First, our study was comparative only, and the absolute error in determining the TB cannot be determined because the exact post-lumpectomy cavity extent is not known. A multidisciplinary approach to boost the breast TB would be useful, such as injection of a contrast agent into the cavity, 3D-US or PET/CT use or MRI simulation and use in contouring the TB. Second, the sample size of this study might lead to uncertainty, as the possibility that the results are not relevant to a larger sample size cannot be excluded.

MATERIALS AND METHODS

Patient selection and instruction

All patients had undergone tumorectomy and sentinel node and/or lymph node dissection for early breast cancer in our department from June 2014 to March 2015, with five or more surgical clips placed in the TB during surgery. These recruited patients were suitable for postoperative treatment with EB-PBI or the simultaneous integrated boost (SIB) technique. Patients with restricted arm movements after surgery or poor pulmonary function were excluded. Written informed consent was obtained from all patients, and the institutional research ethics board of Shandong Cancer Hospital approved this study.

4D-CT data acquisition

Patients were immobilized in a supine position on a breast board, with both arms above their head and positioned on an arm support device during the simulation. A knee support was placed under the knees to fix the patients’ position and improve their comfort.

Free-breathing 4D-CT scans were acquired using a 16-slice CT scanner (Philips Medical Systems, Inc., Cleveland, OH, USA). Respiratory signals were recorded using the Varian Real-Time Position Management (RPM) System (Varian Medical Systems, Palo Alto, CA, USA) by measuring the displacement of infrared markers placed on the epigastric region of the patient’s abdomen. GE Advantage 4D software (GE Healthcare, Waukesha, WI, USA) was used to sort the reconstructed 4D-CT images into ten respiratory phases, labeled as 0 to 90% based on triggered signals. Phase 0% denoted the maximum end inspiration (EI), and phase 50% denoted the maximum end expiration (EE). The 4D-CT images were transferred to the Eclipse Treatment Planning System (TPS) (Eclipse 8.6, Varian Medical Systems, Palo Alto, CA, USA) for structure delineation.

TB contouring methods

First, four radiation oncologists delineated the TB contours on the EE phase for each patient. All four radiation oncologists were given the following criterion for TB delineation: the TB boundaries were defined using a combination of breast tissue changes that were apparent on CT simulation, pathological and radiographic information, fluid collection within the TB, and the number of surgical clips. Second, one experienced radiation oncologist was asked to contour the TB an additional three times to test intraobserver variability. Intraobserver variability and interobserver variability in TB contouring were defined as Δintra, and Δinter, respectively. Δinterintra) was the ratio of the inter(intra)observer TB volume differences in the delineation to the average volume.

TB volume analysis

The Dice similarity coefficient (DSC) was used to determine the extent of spatial overlap between two regions of interest, ranging between 0 (no overlap) and 1 (perfect overlap) [36]. The DSC was defined as

DSC = (2|A∩B|)/(|A∩B|+|A∪B|) × 100%

DSCintra was the percentage ratio for intraobserver variability in TB delineation, and DSCinter was the percentage ratio for interobserver variability in TB delineation.

Statistical analysis

Statistical analysis was performed using the SPSS statistical analysis software package (SPSS Inc., Chicago, IL, USA). T-tests or one-way analysis of variance (ANOVA) was performed to determine the statistical significance of differences in the variability of TB delineation among the different groups, depending on the normality of the data. The Pearson correlation test was also used to examine the relationship between the target variation and influencing factors. A P-value < 0.05 was considered statistically significant. All significance levels were two sided.

CONCLUSIONS

The present study demonstrated that the TB volume and CVS were the primary influencing factors among different observers when 5 or more surgical clips were placed at the TB. However, using more than 6 surgical clips within the TB did not increase the accuracy of TB delineation in 3D EB-PBI or a TB boost for WBI. We note the importance of surgical clips in providing TB delineation and recommend the placement of 5 to 6 surgical clips to allow adequate TB localization following BCS. This approach is also preferable for the purposes of TB delineation. The TB field depends on the surgeon’s choice and relates to tumor size. Breast tissue is nearly always remodeled during breast cancer surgery, with either full-thickness closure of the lumpectomy or superficial closure. Therefore, TB delineation using the seroma or clips may result in geographical misses of the primary tumor after surgery. Further evaluations are thus needed to clearly define the role of the combination of the pre-lumpectomy and postoperative settings in TB contouring.

ACKNOWLEDGMENTS

We acknowledge the contributions of colleagues who previously collected data and contributed to delineating TB contours, including Jun Xing, Min Xu, Qian Shao, and Tingyong Fan.

This manuscript underwent English-language editing by American Journal Experts (AJE).

CONFLICTS OF INTEREST

The authors declare no conflicts of interest.

FINANCIAL SUPPORT

The Medicine and Health Science Technology Development Program of Shandong Province (No. 2013WS0346).

The Science and Technology Program of Shandong Academy of Medical Sciences (No. 2015-62).

The National Key Research Program of China (No. 2016YFC0904700).

REFERENCES

1. Hofvind S, Holen Å, Aas T, Roman M, Sebuødegård S, Akslen LA. Women treated with breast conserving surgery do better than those with mastectomy independent of detection mode, prognostic and predictive tumor characteristics. Eur J Surg Oncol. 2015; 41: 1417-1422.

2. Ye JC, Yan W, Christos PJ, Nori D, Ravi A. Equivalent survival with mastectomy or breast-conserving surgery plus radiation in young women aged < 40 years with early-stage breast cancer: a national registry-based stage-by-stage comparison. Clin Breast Cancer. 2015; 15: 390-397.

3. Kunkler IH, Williams LJ, Jack WJL, Cameron DA, Dixon JM. Breast-conserving surgery with or without irradiation in women aged 65 years or older with early breast cancer (PRIME II): a randomised controlled trial. Lancet Oncol. 2015; 16: 266-273.

4. Wenz F, Sedlmayer F, Herskind C, Welzel G, Sperk E, Neumaier C, Gauter-Fleckenstein B, Vaidya JS, Sutterlin M. Accelerated partial breast irradiation in clinical practice. Breast Care. 2015; 10: 247-252.

5. Ippolito E, Trodella L, Silipigni S, D'Angelillo RM, Di Donato A, Fiore M, Grasso A, Angelini E, Ramella S, Altomare V. Estimating the value of surgical clips for target volume delineation in external beam partial breast radiotherapy. Clin Oncol. 2014; 26: 677-683.

6. Moser EC, Vrieling C. Accelerated partial breast irradiation: the need for well-defined patient selection criteria, improved volume definitions, close follow-up and discussion of salvage treatment. Breast. 2012; 21: 707-715.

7. Dzhugashvili M, Tournay E, Pichenot C, Dunant A, Pessoa E, Khallel A, Gouy S, Uzan C, Garbay J-R, Rimareix F, Spielmann M, Vielh P, Marsiglia H, et al. 3D-conformal accelerated partial breast irradiation treatment planning: the value of surgical clips in the delineation of the lumpectomy cavity. Radiat Oncol. 2009; 4: 70.

8. Dzhugashvili M, Pichenot C, Dunant A, Balleyguier C, Delaloge S, Mathieu MC, Garbay JR, Marsiglia H, Bourgier C. Surgical clips assist in the visualization of the lumpectomy cavity in three-dimensional conformal accelerated partial-breast irradiation. Int J Radiat Oncol Biol Phys. 2010; 76: 1320-1324.

9. Landis DM, Luo W, Song J, Bellon JR, Punglia RS, Wong JS, Killoran JH, Gelman R, Harris JR. Variability among breast radiation oncologists in delineation of the postsurgical lumpectomy cavity. Int J Radiat Oncol Biol Phys. 2007; 67: 1299-1308.

10. Petersen RP, Truong PT, Kader HA, Berthelet E, Lee JC, Hilts ML, Kader AS, Beckham WA, Olivotto IA. Target volume delineation for partial breast radiotherapy planning: clinical characteristics associated with low interobserver concordance. Int J Radiat Oncol Biol Phys. 2007; 69: 41-48.

11. Shaikh T, Chen T, Khan A, Yue NJ, Kearney T, Cohler A, Haffty BG, Goyal S. Improvement in interobserver accuracy in delineation of the lumpectomy cavity using fiducial markers. Int J Radiat Oncol Biol Phys. 2010; 78: 1127-1134.

12. Giezen M, Kouwenhoven E, Scholten AN, Coerkamp EG, Heijenbrok M, Jansen WPA, Mast ME, Petoukhova AL, Struikmans H. MRI- versus CT-based volume delineation of lumpectomy cavity in supine position in breast-conserving therapy: an exploratory study. Int J Radiat Oncol Biol Phys. 2012; 82: 1332-1340.

13. Ford EC, Lavely WC, Frassica DA, Myers LT, Asrari F, Wahl RL, Zellars RC. Comparison of FDG-PET/CT and CT for delineation of lumpectomy cavity for partial breast irradiation. Int J Radiat Oncol Biol Phys. 2008; 71: 595-602.

14. Korreman SS, Pedersen AN, Nøttrup TJ, Specht L, Nyström H. Breathing adapted radiotherapy for breast cancer: comparison of free breathing gating with the breath-hold technique. Radiother Oncol. 2005; 76: 311-318.

15. Borst GR, Sonke JJ, den Hollander S, Betgen A, Remeijer P, van Giersbergen A, Russell NS, Elkhuizen PHM, Bartelink H, van Vliet-Vroegindeweij C. Clinical results of image-guided deep inspiration breath hold breast irradiation. Int J Radiat Oncol Biol Phys. 2010; 78: 1345-1351.

16. Gagel B, Demirel C, Kientopf A, Pinkawa M, Piroth M, Stanzel S, Breuer C, Asadpour B, Jansen T, Holy R, Wildberger JE, Eble MJ. Active breathing control (ABC): Determination and reduction of breathing-induced organ motion in the chest. Int J Radiat Oncol Biol Phys. 2007; 67: 742-749.

17. Qi XS, White J, Rabinovitch R, Merrell K, Sood A, Bauer A, Wilson JF, Miften M, Li XA. Respiratory organ motion and dosimetric impact on breast and nodal irradiation. Int J Radiat Oncol Biol Phys. 2010; 78: 609-617.

18. Liao ZW, Guan XX, Li FY, He ZY, Xue M, Huang XY, Chen LX. Accelerated partial breast irradiation: use of four-dimensional CT for target localization and assessment of intrafractional motion. Oncol Res. 2010; 18: 503-507.

19. Wang W, Bin Li J, Hu HG, Sun T, Xu M, Fan TY, Shao Q. Evaluation of dosimetric variance in whole breast forward-planned intensity-modulated radiotherapy based on 4DCT and 3DCT. J Radiat Res. 2013; 54: 755-761.

20. Ding Y, Li J, Wang W, Wang S, Wang J, Ma Z, Shao Q, Xu M. A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery. Radiat Oncol. 2014; 9: 76.

21. Wang S, Li J, Wang W, Zhang Y, Li F, Fan T, Shang D. A study on the displacements of the clips in surgical cavity for external-beam partial breast irradiation after breast-conserving surgery based on 4DCT. J Radiat Res. 2012; 53: 433-438.

22. Kirova YM, Pena PC, Hijal T, Fournier-Bidoz N, Laki F, Sigal-Zafrani B, Dendale R, Bollet MA, Campana F, Fourquet A. Improving the definition of tumor bed boost with the use of surgical clips and image registration in breast cancer patients. Int J Radiat Oncol Biol Phys. 2010; 78: 1352-1355.

23. Thureau S, Oden S, Mokaouim R, Mezzani-Saillard S, Clatot F, Hanzen C. Assessing the contribution of a standardized method in defining the tumor bed using surgical clips in breast cancer. Cancer Radiother. 2012; 16: 100-106.

24. Boersma LJ, Janssen T, Elkhuizen PHM, Poortmans P, van der Sangen M, Scholten AN, Hanbeukers B, Duppen JC, Hurkmans C, van Vliet C. Reducing interobserver variation of boost-CTV delineation in breast conserving radiation therapy using a pre-operative CT and delineation guidelines. Radiother Oncol. 2012; 103: 178-182.

25. Kirby AM, Jena R, Harris EJ, Evans PM, Crowley C, Gregory DL, Coles CE. Tumour bed delineation for partial breast/breast boost radiotherapy: what is the optimal number of implanted markers? Radiother Oncol. 2013; 106: 231-235.

26. De Ruysscher D, Faivre-Finn C, Nestle U, Hurkmans CW, Le Pechoux C, Price A, Senan S. European organisation for research and treatment of cancer recommendations for planning and delivery of high-dose, high-precision radiotherapy for lung cancer. J Clin Oncol. 2010; 28: 5301-5310.

27. Zhang Y, Zhou Y, Yang X, Tang P, Qiu Q, Liang Y, Jiang J. Thin slice three dimentional (3D) reconstruction versus CT 3D reconstruction of human breast cancer. Indian J Med Res. 2013; 137: 57-62.

28. Guo B, Li J, Wang W, Xu M, Shao Q, Zhang Y, Liang C, Guo Y. Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation. Radiat Oncol. 2015; 10: 66.

29. Guo B, Xu M, Li JB, Wang W, Li YK, Liu T. A comparison of dosimetric variance for external-beam partial breast irradiation using three-dimensional and four-dimensional computed tomography. Onco Targets Ther. 2016; 9: 1857-1863.

30. Wang W, Li J, Hu H, Li F, Xu M, Sun T, Lu J. Correlation between target motion and the dosimetric variance of breast and organ at risk during whole breast radiotherapy using 4DCT. Radiat Oncol. 2013; 8: 111.

31. Cover KS, Lagerwaard FJ, Senan S. Color intensity projections: a rapid approach for evaluating four-dimensional CT scans in treatment planning. Int J Radiat Oncol Biol Phys. 2006; 64: 954-961.

32. Berrang TS, Truong PT, Popescu C, Drever L, Kader HA, Hilts ML, Mitchell T, Soh SY, Sands L, Silver S, Olivotto IA. 3D ultrasound can contribute to planning CT to define the target for partial breast radiotherapy. Int J Radiat Oncol Biol Phys. 2009; 73: 375-383.

33. Whipp EC, Halliwell M. Magnetic resonance imaging appearances in the postoperative breast: the clinical target volume–tumor and its relationship to the chest wall. Int J Radiat Oncol Biol Phys. 2008; 72: 49-57.

34. Kader HA, Truong PT, Pai R, Panades M, Jones S, Ansbacher W, Olivotto IA. When is CT-based postoperative seroma most useful to plan partial breast radiotherapy? Evaluation of clinical factors affecting seroma volume and clarity. Int J Radiat Oncol Biol Phys. 2008; 72: 1064-1069.

35. Lewis L, Cox J, Morgia M, Atyeo J, Lamoury G. A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time. J Med Radiat Sci. 2015; 62: 177-183.

36. Ehler ED, Tome WA. On correlated sources of uncertainty in four dimensional computed tomography data sets. Technol Cancer Res Treat. 2010; 9: 299-306.


Creative Commons License All site content, except where otherwise noted, is licensed under a Creative Commons Attribution 4.0 License.
PII: 12044