Introduction

The pelvic lymph nodes are a common site of recurrent prostate cancer after surgery or radiation. Evidence based largely on the levels of prostate-specific antigen (PSA) in biochemical recurrence indicate that the sooner treatment, typically consisting of radiation and androgen deprivation therapy (ADT), is instituted after detection, the better is survival [1]. This increases the importance of early detection and localization of recurrent disease, whether in the lymph nodes or in the prostatic bed (Figs. 1, 2, 3 and 4).

Fig. 1
figure 1

A 67-year-old patient with recurrent prostate cancer after prostatectomy. a The 68Ga-PSMA PET maximum intensity projection demonstrates multiple positive nodes in the pelvis abdomen, thorax and neck. b–d The CT image (b), PET/CT image (c) and PET image (d) show a single axial slice in the pelvis demonstrating three PSMA-positive nodes (arrows)

Fig. 2
figure 2

Image processing of a PSMA-positive node. The node corresponding to the positive 68Ga-PSMA PET images (a, d SUVmax 5.82) is represented on the CT images (b axial, c coronal, and f sagittal planes). It was segmented using Fraunhofer MEVIS software enabling automated quantification of the dimensions (short-axis diameter 4.19 mm, long-axis diameter 6.76 mm). e Volume rendering of the segmented node also provided by the software

Fig. 3
figure 3

Volume (a), short-axis diameter (b) and long-axis diameter (c) of PSMA positive lymph nodes indicating that 68Ga-PSMA PET/CT is able to detect many metastatic nodes smaller than the standard size for positive lymph nodes on CT or MRI (diameter >1 cm, volume >0.5 cm3)

Fig. 4
figure 4

Morphological distribution of all 49 PSMA-positive lymph nodes in terms of their short-axis diameter (a) and long-axis diameter (c). The relationships between SUVmax and the short axis diameter (b) and long axis diameter (d) of the PSMA-positive lymph nodes are also shown

Current methods for assessing lymph nodes in the recurrence setting are limited. Although pelvic lymph node dissection is considered the most reliable procedure for assessing the presence of nodal invasion in the primary setting, this is often impractical in the recurrence setting [2]. CT is commonly used for nodal staging. However, CT has a limited ability to predict lymph node invasion because of its low sensitivity for small-volume or micrometastatic disease [35]. In order to avoid excessive false-positive findings, the normal upper limit of the short-axis diameter of pelvic lymph nodes is usually set at 7 – 10 mm depending on the location. However, up to 80 % of metastatic lymph nodes in prostate cancer have a short-axis diameter less than 7 mm [36]. Similar comments apply to MRI which has classically relied on size criteria alone, although there has been recent interest in the use of diffusion-weighted MRI in this setting [7]. Thus, morphological criteria alone are highly limited in their ability to predict lymph node recurrence.

A new imaging method, PSMA PET/CT, has recently been introduced to evaluate prostate cancer. Prostate-specific membrane antigen (PSMA) is highly expressed in many prostate cancers and correlates with traditional negative prognostic factors such as a high Gleason score, metastasis or recurrent disease, but is not found in most other tissues [8]. Thus PSMA-targeted PET agents have considerably more specificity than conventional anatomic imaging. However, it is not clear that PET/CT with the 68Ga-PSMA ligand has superior sensitivity to CT alone, given the lower spatial resolution of PET in comparison with CT. For instance, typical PET scanners have a spatial resolution of 3 – 5 mm, whereas CT has submillimetre resolution, and it might be that only larger nodes are detectable by PET.

Therefore, we aimed to determine if PET/CT with 68Ga-PSMA-11 is capable of detecting nodal metastases below the conventional CT size thresholds for nodal metastasis.

Materials and methods

Patients

In this retrospective investigation we evaluated a total of 49 PET-positive lymph nodes in 21 consecutive patients (median age 70 years, range 54–79 years) referred to radiooncology with biochemical recurrence (i.e. rising PSA) of prostate cancer following radical prostatectomy (initial mean PSA level 6.84 ng/ml, range 0.6 – 45 ng/ml). The patients included in this investigation had a mean Gleason score of 8 (range 6 – 9). All patients the D’Amico risk category was intermediate or high at diagnosis (Table 1). All patients signed a written informed consent form for the purposes of anonymized evaluation and publication of their data. All reported investigations were conducted in accordance with the principles of the Declaration of Helsinki and with our national regulations. This evaluation was approved by the Ethics Committee of the University of Heidelberg.

Table 1 Patient demographics

Image acquisition, PSMA PET analysis and volumetric CT histogram analysis

All PET/CT examinations were done on a Biograph 6 PET/CT scanner (Siemens/CTI). Imaging was started 60 ± 10 min after intravenous injection of 68Ga-PSMA-11 at a median dose of 176 MBq (range 79 – 317 MBq). For attenuation correction of the PET scan, a CT scan (130 keV, 80 mAs; CareDose) without contrast medium was performed. Static emission scans, corrected for dead time, scatter and decay, were acquired from the vertex to the proximal legs, requiring eight bed positions with 3 min per bed position. The images were iteratively reconstructed with the OSEM algorithm using four iterations with eight subsets and Gaussian filtering to an in-plane spatial resolution of 5 mm at full-width at half-maximum. For calculation of the standardized uptake value (SUV), circular regions of interest were drawn around the area with focally increased uptake in transaxial slices and automatically adapted to a three-dimensional volume of interest with e.soft software (Siemens) at a 70 % isocontour. The CT scan was reconstructed with a B30 kernel to a slice thickness of 5 mm with an increment of 2.5 mm. Lymph nodes were considered PSMA-positive when the maximum SUV (SUVmax) was >2. This cut-off value was chosen after evaluating the blood pool at 60 min after injection in the aorta, which was found to have a mean ± standard deviation SUVmax of 1.49 ± 0.49.

Volumetric CT analysis was performed on PET-positive nodes using semiautomated software (Fraunhofer MEVIS, Bremen, Germany) that segments the nodes and automatically determines mean density, short-axis diameter, long-axis diameter and volume. Semiautomatic three-dimensional histogram analysis is initiated after the user provided a seed point in the lymph node and the software found the margins of the node. The segmentation starts with a fixed-width thresholding around the seed point. To remove attached vessels, muscles or other lymph nodes, a watershed transform is performed on the distance map of the thresholding result. The watershed transform is controlled by include and exclude markers which are set according to an ellipsoid approximation of the lymph node. The volumes were evaluated by a radiologist to ensure that no extraneous tissue was segmented and manually corrected in all three dimensions, if necessary.

Statistical evaluation

Nodes with a diameter more than 8 mm were accepted as positive for metastasis on CT [9, 10]. Descriptive statistics defining the percent positive PET/CT scans with nodes smaller than the above size criteria were calculated. Pearson coefficients were calculated using Excel (Microsoft, Seattle, WA).

Results

A total of 49 lymph nodes in 21 patients could clearly be correlated with nodal uptake on 68Ga-PSMA ligand PET/CT. By study definition all 49 lymph nodes demonstrated 68Ga-PSMA ligand uptake on PET/CT with a mean SUVmax of 7.43 (range 1.8 – 25.2). Among the 49 PSMA-positive lymph nodes, 38 (78 %) were morphologically negative (<8 mm) and 11 (22 %) were morphologically positive on conventional imaging (≥8 mm) (Fig. 4). All 49 lymph nodes were analysed with the semiautomated segmentation software. Semiautomatic segmentation required less than 5 min per patient but enabled derivation of several important parameters: lymph-node size (short and long axis) and lymph-node volume. The interobserver and intraobserver reproducibility was good with a coefficient of variation <5 % when the software was evaluated for reliability in a recent study [11].

The mean volume of all 49 lymph nodes was 0.5 ml (range 0.2 – 2.3 ml), the mean short-axis diameter was 5.8 mm (range 2.4 – 13.3 mm) and the mean long axis diameter was 9.5 mm (range 4.7 – 19.3 mm). In seven patients (33 %) at least one node was larger than the conventional criteria for morphological positivity. However, among the 31 PSMA-positive nodes in these patients only 11 (36 %) were ≥8 mm on the CT scan with a mean short-axis diameter of 11.8 mm (range 8.4 – 19.1 mm). None of 14 patients (67 %) with 18 PSMA-positive lymph nodes met the morphological criteria for positivity. In this group, the mean short-axis diameter was 5.0 mm (range 2.4 – 7.9 mm) and the mean PSMA SUVmax was 5.5 (range 1.8 – 13.1). Thus, the N stage was changed from N0 to N1 in 14 of 21 patients (67 %) in this cohort on 68Ga-PSMA ligand PET/CT.

Discussion

PSA testing after surgery or radiation therapy for prostate cancer permits the early identification of patients with biochemical recurrence. There is evidence that early treatment may result in better outcomes [1]. However, localization of the site of recurrence has proven to be difficult and thus empirical therapies such as pelvic irradiation and ADT have been employed. However, such treatments are given without specific regard to the location of the recurrence. Localizing the exact sites of recurrence could permit a more targeted approach with fewer side effects. In patients with single lesions surgery with curative intent may be performed although this is controversial. Other options include targeted ablation, focal radiation and even molecular and immunomodulatory therapies. Missing from the current clinical decision tree, however, is an effective means of detecting and monitoring recurrence sites while this “therapeutic window” is still open.

A common site of recurrent disease in prostate cancer is the pelvic lymph nodes. However, the existing methods for detection of nodes such as CT or MRI are nonspecific. Enlargement of round nodes beyond 8 mm is considered a positive finding with a low sensitivity of approximately 34 – 40 % and a moderate/high specificity (80 – 97 %) [9, 10, 12]. Just as small nodes below the size threshold are commonly missed, large lymph nodes above the size threshold may simply represent nodal hyperplasia. For this reason, CT and MRI are not considered reliable enough for routine nodal staging [2]. A source of considerable error in studies of lymph nodes is the variability in the manual measurement of lymph node size. Volumetric analysis allows a more precise and objective assessment of tumour burden. It was first introduced for pulmonary nodules and recently was made clinically available with special software packages [13]. CT volumetric analysis software (Fraunhofer MEVIS) was used to precisely determine nodal volume. This enabled reliable and rapid nodal measurements in this study.

As reported recently, enhanced uptake of 68Ga-PSMA-11 correlated well with the surgical pathology in 42 patients [14]. In 319 patients evaluated with follow-up as the standard of reference, sensitivity and specificity were found to be 76.6 % and 100 %, and the negative and positive predictive values were 91.4 % and 100 %, respectively [14]. Due to the positive predictive value of 100 % in this large study with a thoroughly defined gold standard, a positive PSMA PET was considered as the standard of reference for lymph node involvement in our investigation. Nevertheless, PSMA is not specific for prostate cancer but can also be found in the neovasculature of other solid tumours (thyroid, colon, kidney, glioblastoma). Thus, false-positive lymph node metastases can occur in patients with secondary malignancies. Nevertheless, the likelihood that PSMA-positive lymph nodes found in the typical lymph drainage region of the prostate are true-positive can be considered to be close to 100 %. In our small patient population we did not observe PET-positive lymph nodes in uncommon locations, which would have to be interpreted more cautiously with regard to the possibility of a second malignancy.

In this analysis, 21 patients with recurrent prostate cancer who underwent 68Ga-PSMA-11 PET/CT were evaluated. Among the 21 patients, only 7 (33 %) harboured nodes that exceeded the size criterion for metastases on CT. This is consistent with existing data on the sensitivity of CT. However, the remaining 14 patients who were considered normal by CT criteria were actually shown to harbour metastases in small nodes not meeting the size criterion for positivity on CT. Further, only 11 (22.45 %) of the 49 PSMA-positive nodes met the size criterion for metastasis on CT. Thus, using standard TNM staging only one-third of the patients in this study would have been considered cN1 by CT criteria. The use of PSMA PET/CT imaging led to the reclassification of another 14 patients from cN0 to cN1. In a previous study evaluating patients with prostate cancer prior to first-line radiotherapy, 68Ga-PSMA-11 PET/CT led to a change in TNM staging due to a change from cN0 to cN1 in nearly 40 % of patients. This result is in line with the results of our current investigation [15].

In the past, other PET imaging tracers have also been used in the setting of biochemical recurrence. 11C-Choline is one such agent that has shown variable success in this setting [13, 16, 17]. Other PET tracers include 18F-fluoromethyl choline (18F-FMCh), 18F-fluoroethyl choline (18F-FECh), 11C-acetate, 18F-FACBC (radiofluorinated aminocyclobutane carboxylic acid) and 18F-FDHT (radiofluorinated dihydrotestosterone), but none has emerged as clearly superior to any other. Our initial experience with 68Ga-PSMA-11 PET/CT suggests that this novel tracer can detect relapses and metastases with high contrast by binding to the extracellular catalytic domain of PSMA, followed by internalization [18, 19].

A significant advantage of PSMA PET/CT is that PSMA-11 uptake in lymph node and other soft tissue metastases is higher than that of other agents [1921]. Another promising recently introduced PSMA ligand labelled with 18F showed similar contrast ratios in a small cohort of seven patients [22]. A potential disadvantage is that tumoral PSMA expression may be modulated by the androgen receptor. In preclinical studies based on cell lines, antiandrogens initially upregulated PSMA expression [22] while prolonged ADT seemed to downregulate PSMA over time [23, 24] but might also induce upregulation after ADT is withdrawn [14]. In contrast, 68Ga-PSMA-11 PET/CT was more frequently positive in patients receiving ADT at the time of the scan than in patients without such treatment [25]. Thus further clinical studies are necessary to draw a final conclusion on the impact of ADT on the expression of tumour PSMA in humans.

Conclusion

In this study, two-thirds of patients with recurrent prostate cancer were upstaged from cN0 to cN1 based on their 68Ga-PSMA-11 PET/CT scan. The majority (78 %) of nodes detected by 68Ga-PSMA-11 PET/CT were smaller than 8 mm in diameter and therefore did not meet standardized morphological criteria for metastatic nodes. Thus, 68Ga-PSMA-11 PET/CT appears to be a promising method of restaging patients with suspected recurrent prostate cancer based on elevated PSA levels. The ability of 68Ga-PSMA-11 PET/CT to detect focal sites of disease in recurrent prostate cancer with high sensitivity opens the possibility for early targeted therapies. In the case of single lesions, a surgical approach may be considered, although data are currently sparse. Other options include targeted ablative technologies or focal radiation. Further investigations are necessary to demonstrate which of these treatment modalities can really benefit from improved diagnostic sensitivity.