RT Journal Article SR Electronic T1 Plan Quality Comparisons Between 3D-CRT, IMRT, and VMAT Based on 4D-CT for Gastric MALT Lymphoma JF Anticancer Research JO Anticancer Res FD International Institute of Anticancer Research SP 3941 OP 3947 DO 10.21873/anticanres.15190 VO 41 IS 8 A1 TADASHI MATSUMOTO A1 RYO TOYA A1 YOSHINOBU SHIMOHIGASHI A1 TAKAHIRO WATAKABE A1 TOMOHIKO MATSUYAMA A1 TETSUO SAITO A1 YOSHIYUKI FUKUGAWA A1 YUDAI KAI A1 NATSUO OYA YR 2021 UL http://ar.iiarjournals.org/content/41/8/3941.abstract AB Background/Aim: We compared three-dimensional conformal RT (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric modulated arc therapy (VMAT) for gastric mucosa-associated lymphoid tissue (MALT) lymphoma using four-dimensional computed tomography (4D-CT) images. Patients and Methods: Three treatment plans of 3D-CRT, IMRT, and VMAT with 30 Gy were created based on 4D-CT images of seven patients. We calculated D95, homogeneity index (HI), and conformity index (CI) of planning target volume, and organs at risk doses. Results: There was no significant difference among the three plans in D95. HI of the IMRT plan was significantly better than that of the VMAT (p=0.047) and 3D-CRT (p=0.047) plans. CIs of the IMRT and VMAT plans were significantly better than those of the 3D-CRT plan (p=0.047 and p=0.047, respectively). Dmean of the liver for 3D-CRT was significantly higher than that for the IMRT (p=0.047) and VMAT (p=0.047) plans. Conclusion: The IMRT plan yields the best plan quality for gastric MALT lymphoma.