Skip to main content

Main menu

  • Home
  • Current Issue
  • Archive
  • Info for
    • Authors
    • Editorial Policies
    • Subscribers
    • Advertisers
    • Editorial Board
    • Special Issues
  • Journal Metrics
  • Other Publications
    • In Vivo
    • Cancer Genomics & Proteomics
    • Cancer Diagnosis & Prognosis
  • More
    • IIAR
    • Conferences
    • 2008 Nobel Laureates
  • About Us
    • General Policy
    • Contact
  • Other Publications
    • Anticancer Research
    • In Vivo
    • Cancer Genomics & Proteomics

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Anticancer Research
  • Other Publications
    • Anticancer Research
    • In Vivo
    • Cancer Genomics & Proteomics
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Anticancer Research

Advanced Search

  • Home
  • Current Issue
  • Archive
  • Info for
    • Authors
    • Editorial Policies
    • Subscribers
    • Advertisers
    • Editorial Board
    • Special Issues
  • Journal Metrics
  • Other Publications
    • In Vivo
    • Cancer Genomics & Proteomics
    • Cancer Diagnosis & Prognosis
  • More
    • IIAR
    • Conferences
    • 2008 Nobel Laureates
  • About Us
    • General Policy
    • Contact
  • Visit us on Facebook
  • Follow us on Linkedin
Research ArticleClinical Studies
Open Access

The ColonView (CV) Quick Test for Fecal Occult Blood Shows Significantly Higher Diagnostic Accuracy in Detecting Distal than Proximal Colorectal Cancer

MAARET ESKELINEN, JANNICA MEKLIN, DENISE PEIXOTO GUIMARÃES, TUOMAS SELANDER, TAPANI TIUSANEN, KARI SYRJÄNEN and MATTI ESKELINEN
Anticancer Research April 2022, 42 (4) 1879-1891; DOI: https://doi.org/10.21873/anticanres.15664
MAARET ESKELINEN
1Department of Surgery, Kuopio University Hospital and School of Medicine, University of Eastern Finland, Kuopio, Finland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: matti.eskelinen{at}kuh.fi
JANNICA MEKLIN
1Department of Surgery, Kuopio University Hospital and School of Medicine, University of Eastern Finland, Kuopio, Finland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
DENISE PEIXOTO GUIMARÃES
2Molecular Oncology Research Center, Barretos Cancer Hospital, Barretos, Brazil;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
TUOMAS SELANDER
3Science Service Center, Kuopio University Hospital and School of Medicine, University of Eastern Finland, Kuopio, Finland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
TAPANI TIUSANEN
4Department of Clinical Research, Biohit Oyj, Helsinki, Finland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
KARI SYRJÄNEN
2Molecular Oncology Research Center, Barretos Cancer Hospital, Barretos, Brazil;
5SMW Consultants, Ltd., Kaarina, Finland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
MATTI ESKELINEN
1Department of Surgery, Kuopio University Hospital and School of Medicine, University of Eastern Finland, Kuopio, Finland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Aim: The present study compared the accuracy of ColonView (CV) quick test in detecting proximal versus distal colorectal cancer (CRC). A traditional guaiac-based fecal occult blood test (gFOBT) (Hemoccult SENSA) was used as a reference. Patients and Methods: A cohort of 368 colonoscopy-referral patients were asked to collect 3 consecutive fecal samples, to be analyzed by both assays (CV, SENSA). Receiver operating characteristic (ROC) analysis was used to find the optimal cut-off values for both Hb and Hb/Hp of the CV test. Summary hierarchical ROC (HSROC) curves were used to visualize the pooled overall accuracy of visually analysed (VA) and automatically analyzed (AA) reading modes in proximal and distal CRC detection. Results: The overall specificity (Sp) of the AA reading mode for the proximal CRC and distal CRC endpoint was 73% and 76%, respectively. For proximal CRC, the two most sensitive AA tests showed 90% sensitivity (Se), while for distal CRC, the two most sensitive AA tests showed 100% Se. In the HSROC analysis, the AUC values were as follows: i) VA in proximal CRC: 0.765, ii) AA in proximal CRC: 0.878, iii) VA in distal CRC: 0.955 and iv) AA in distal CRC: 0.961. In roccomp analysis, AUC values were significantly different in: VA vs. AA in proximal CRC p=0.009; VA in proximal vs. VA in distal CRC p<0.0001; VA in proximal vs. AA in distal CRC p<0.0001; AA in proximal vs. VA in distal CRC p=0.021; AA in proximal CRC vs. AA in distal CRC p=0.006. Conclusion: The applicability of the CV test (a new-generation FIT) in CRC screening was confirmed. The AA reading was superior to VA (or SENSA) in its diagnostic accuracy in detecting proximal CRC patients. Distal CRCs were more accurately detected than proximal CRCs by both reading modes.

Key Words:
  • Fecal immunochemical test
  • FIT
  • colorectal cancer screening
  • ROC
  • proximal colon
  • distal colon

Colorectal cancer (CRC) is the third common cancer and fourth common cause of cancer-related death worldwide with 1,850 000 new cases and 880,000 deaths occurring in 2018 (1). European Guidelines (2) based on previous randomized trials suggest that annual or biennial fecal occult blood (FOB) screening associated with a 15-33% decrease in CRC mortality rates (2–4).

Bleeding in colorectal neoplasms (CRN) is usually intermittent with varying in degree and therefore FOB and Hb is measured using either simple guaiac-based fecal occult blood tests (gFOBTs) or more recently introduced fecal immunochemical tests (FITs) (2–4). A significant technical enhancement is achieved by using an antibody specific to human globin, the protein component of Hb. Immunochemical test technology (FITs) enables detection of bleeding and Hb at lower concentrations than gFOBTs and therefore have several advantages, including improved clinical performance and higher efficiency by detecting smaller CRN with intermittent bleeding (2–4). In several modern FITs the cut-off concentrations are adjusted with a reader device and such device can provide possibility to automate the test process (2). The latest development in this field represents a second-generation FIT test (ColonView® quick test) (CV), having the advantage of measuring two components of FOB; Hb and Hb/Hp complex (3–4).

There is increasing evidence suggesting that the diagnostic performance of FOBTs may depend on the anatomical site of CRC, as discussed in three recent reviews (6–8). Unfortunately, the CV test was not included in these analyses; however, the present study is the first where the diagnostic accuracy of the CV test was compared in detection of the proximal and distal CRCs. This analysis was extended by applying hierarchical summary receiver operating characteristic (HSROC) analysis to test the different cut-offs and to assess the diagnostic performance of the CV test in colonoscopy-referral screening patients.

Patients and Methods

The Barretos Cancer Hospital (BCH) colorectal neoplasia (CRN) screening cohort included 5,090 individuals (Figure 1). Detailed description of all detected lesions was provided, including their number, size and exact locations: proximal (from cecum to splenic flexure) or distal (descending colon to rectum). The study protocol and inclusion/exclusion criteria of study patients were detailed in a previous report by Guimaraes et al. (9).

Figure 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 1.

Flow-chart of the study.

Sample collection, processing, and interpretation of results. A new-generation FIT, ColonView® quick test (CV) (Biohit Oyj, Helsinki, Finland) does not necessitate any preparatory steps of the patient or compliance with any restrictions in the daily diet or medication. The guaiac-based traditional FOBT (Hemoccult SENSA, Beckman Coulter Inc., Pasadena, CA, USA) was used as the reference in this study. The sample collection protocol of both tests was described in more detail recently (9).

For the CV test, two optional reading modes are available: visual analysis (VA) and automatic analysis (AA). The latter is performed by using opTrilyzer Lateral flow reader (Chembio Diagnostics GmbH, Berlin, Germany), as described before (9–10). The analytical sensitivity for CV Hb is 15 ng/ml, and for CV Hb/Hp complex, 4 ng/ml (11, 12).

Statistical analysis. STATA/SE version 17.0 (StataCorp, College Station, TX, USA) and MetaDiSc software 1.4 (Meta Analysis of Diagnostic and Screening Test; Unit of Clinical Biostatistics team of the Ramón y Cajal Hospital, Madrid, Spain) were used for analysis. The statistical tests performed were two-sided, and p-values <0.05 were considered statistically significant. Using 2×2 tables, sensitivity (Se) and specificity (Sp) with 95% confidence intervals (95% CI) for each FOB test was determined. Conventional receiver operating characteristic (ROC) analysis was used to graph for Se and Sp and to find the optimal cut-off values for both Hb and Hb/Hp of the CV test (Figure 2). Meta-analytical technique (metaprop; Stata) was used to create separate forest plots for Se and Sp, with each set of data included (i.e., test components Hb, Hb/Hp, cut-offs). We also calculated the summary estimates of Se and Sp, positive (LR+) and negative likelihood ratio (LR-) as well as diagnostic odds ratio, using a random effects bivariate model and fitted the summary hierarchical ROC (HSROC; MetaDiSc) curves for the CRC as the endpoint. Roccomp test (Stata) was used to compare the statistical significance between the area under the curve (AUC) values of AA and VA modes for proximal and distal CRC endpoint.

Figure 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 2.

Receiver operating characteristic (ROC) curve for test optimization and finding optimal cut-off point for automatically analyzed (AA) ColonView (CV) Hb and Hb/Hp tests in proximal and distal colorectal cancer (CRC) endpoints.

Results

Proximal CRC endpoint with VA tests. The Se, Sp and efficiency of the SENSA test for CRC were as follows: 57.0%, 78.0% and 76.2% (Table I, Figure 3 and Figure 4). The Se, Sp and efficiency of the visually analysed CV Hb and CV Hb/Hp tests for CRC were as follows: 86.0/86.0%, 51.0/56.0% and 54.1/58.9% (Table I, Figure 3 and Figure 4). The positive predictive value (PV+) of the CV Hb/Hp VA test was slightly higher than that of the CV Hb VA test (17.8% vs. 16.5%; Table I). When CV Hb + Hb/Hp VA were used as a combined test panel for the CRC endpoint, the panel had 86% Se, 48% Sp and 52.2% efficiency (Table I, Figure 3 and Figure 4).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table I.

Visually analyzed screening tests for proximal colorectal cancer endpoint.

Figure 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 3.

Sensitivity values of visually analyzed (VA) screening tests for proximal colorectal cancer endpoint. ES: Estimated sensitivity; CI: confidence interval.

Figure 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 4.

Specificity values of visually analyzed (VA) screening tests for proximal colorectal cancer endpoint. ES: Estimated specificity; CI: confidence interval.

Proximal CRC endpoint with AA tests. The overall Se of the AA reading mode for proximal CRC was 84.0% (95% CI=75-92%) (Table II, Figure 5 and Figure 6). The two most sensitive AA tests (CV Hb AA at cut-off ≥11.61 reader units (RU) and CV Hb/Hp AA at cut off ≥7.48 RU) showed 90% Se (Table II, Figure 5). The overall Sp of the AA reading mode for the proximal CRC endpoint was 73% (95% CI=52-89%; Figure 6). The two most specific AA tests (CV Hb AA at cut-off ≥158.8 RU, CV Hb/Hp AA at cut-off ≥54.62 RU) in proximal CRC diagnosis showed Sp range of 84-90% (Figure 6).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table II.

Automatically analyzed screening tests for proximal colorectal cancer endpoint.

Figure 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 5.

Sensitivity values of automatically analyzed (AA) screening tests for proximal colorectal cancer endpoint. ES: Estimated sensitivity; CI: confidence interval.

Figure 6.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 6.

Specificity values of automatically analyzed (AA) screening tests for proximal colorectal cancer endpoint. ES: Estimated specificity; CI: confidence interval.

Distal CRC endpoint with VA tests. The Se, Sp and efficiency of the SENSA test for distal CRC were as follows: 95%, 87% and 88.2% (Table III, Figure 7 and Figure 8). The Se, Sp and efficiency of the visually analysed CV Hb and CV Hb/Hp tests for distal CRC were as follows: 100%/100%, 70%/58% and 75.0%/65.3% (Table III, Figure 7 and Figure 8). The PV+ of the CV Hb VA test was slightly higher than that of the CV Hb/Hp VA test (41.9% vs. 33.3%; Table III). When CV Hb + Hb/Hp VA were used as a combined test panel for the CRC endpoint, the panel had 100% Se, 56% Sp and 64.0% efficiency (Table III, Figure 7 and Figure 8).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table III.

Visually analyzed screening tests for distal colorectal cancer endpoint.

Figure 7.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 7.

Sensitivity values of visually analyzed (VA) screening tests for distal colorectal cancer endpoint. ES: Estimated sensitivity; CI: confidence interval.

Figure 8.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 8.

Specificity values of visually analyzed (VA) screening tests for distal colorectal cancer endpoint. ES: Estimated specificity; CI: confidence interval.

Distal CRC endpoint with AA tests. The overall Se of the AA reading mode for distal CRC was 98% (95% CI=92-100%) (Table III, Figure 9). The two most sensitive AA tests (CV Hb AA at cut-off ≥9.13 RU and CV Hb/Hp AA at cut off ≥10.78 RU) showed 100% Se (Figure 9). The overall Sp of the AA reading mode for the distal CRC endpoint was 76% (95% CI=58-90%; Figure 10). The two most specific AA tests (CV Hb AA at cut-off ≥43.83 RU, CV Hb/Hp AA at cut-off ≥47.65 RU) in distal CRC diagnosis showed Sp range of 87-90% (Figure 10).

Figure 9.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 9.

Sensitivity values of automatically analyzed (AA) screening tests for distal colorectal cancer endpoint. ES: Estimated sensitivity; CI: confidence interval.

Figure 10.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 10.

Specificity values of automatically analyzed (AA) screening tests for distal colorectal cancer endpoint. ES: Estimated specificity; CI: confidence interval.

ROC analysis and optimal cut-off values of the CV for proximal CRC endpoint. The ROC analysis (Figure 2) for proximal CRC endpoint showed the optimal cut-off value of ≥158.80 RU for CV Hb AA (Table II) and ≥54.62 RU for CV Hb/Hp AA (Table II). Using these cut-offs, the Se, Sp and efficiency of the CV Hb AA (Table II) and CV Hb/Hp AA (Table II) tests for CRC were as follows: 71.4/81.0%, 90.3/83.9% and 88.4/83.8%. The PV+ of CV Hb AA (Table II) was significantly higher than that of test CV Hb/Hp AA (Table II); 45.5% vs. 36.2%.

ROC analysis and optimal cut-off values of the CV for distal CRC endpoint. The ROC analysis (Figure 2) for distal CRC endpoint showed the optimal cut-off value of ≥43.83 RU for CV Hb AA (Table IV) and ≥47.65 RU for CV Hb/Hp AA (Table IV). Using these cut-offs, the Se, Sp and efficiency of the CV Hb AA (Table IV) and CV Hb/Hp AA (Table IV) tests for CRC were as follows: 94.4%/94.1%, 90.2/86.6% and 91.0/87.9%. The PV+ of CV Hb AA (Table IV) was significantly higher than that of test CV Hb/Hp AA (Table IV); 68.0% vs. 59.3%.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table IV.

Automatically analyzed screening tests for distal colorectal cancer endpoint.

HSROC and AUC values. HSROC curves were used to visualize the pooled overall accuracy of VA and AA reading modes in proximal and distal CRC detection. In the HSROC analysis, the AUC values were as follows: i) VA in proximal CRC: AUC=0.765 (95% CI=0.680-0.845) (Figure 11), ii) AA in proximal CRC: AUC=0.878 (95% CI=0.808-0.948) (Figure 12), iii) VA in distal CRC: AUC=0.955 (95% CI=0.901-0.999) (Figure 13) and iv) AA in distal CRC: AUC=0.961 (95% CI=0.904-1.000) (Figure 14). In roccomp analysis, statistical significance of the differences in AUC values was: VA vs. AA in proximal CRC p=0.009; VA in proximal vs. VA in distal CRC p<0.0001; VA in proximal vs. AA in distal CRC p<0.0001; AA in proximal vs. VA in distal CRC p=0.021; AA in proximal CRC vs. AA in distal CRC p=0.006; and VA vs. AA in distal CRC p=0.809.

Figure 11.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 11.

Hierarchical summary receiver operating characteristic (HSROC) curve of the visually analyzed (VA) screening tests for proximal colorectal cancer endpoint. The upper and lower lines represent the 95% confidence interval (CI) of the summary ROC curve. The red dots represent the combinations of the ColonView/SENSA tests as shown in the Tables. SE(Q*), standard error of the Q* index.

Figure 12.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 12.

Hierarchical summary receiver operating characteristic (HSROC) curve of the automatically analyzed (AA) screening tests for proximal colorectal cancer endpoint. The upper and lower lines represent the 95% confidence interval (CI) of the summary ROC curve. The red dots represent the combinations of the ColonView tests as shown in the Tables. SE(Q*), standard error of the Q* index.

Figure 13.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 13.

Hierarchical summary receiver operating characteristic (HSROC) curve of the visually analyzed (VA) screening tests for distal colorectal cancer endpoint. The upper and lower lines represent the 95% confidence interval (CI) of the summary ROC curve. The red dots represent the combinations of the ColonView/SENSA tests as shown in the Tables. SE(Q*), standard error of the Q* index.

Figure 14.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 14.

Hierarchical summary receiver operating characteristic (HSROC) curve of the automatically analyzed (AA) screening tests for distal colorectal cancer endpoint. The upper and lower lines represent the 95% confidence interval (CI) of the summary ROC curve. The red dots represent the combinations of the ColonView tests as shown in the Tables. SE(Q*), standard error of the Q* index.

Discussion

Relatively few FITs have been tested for clinical Se and Sp in CRC screening settings (3, 4). In addition, most FITs on the market are based on the detection of the globin moiety of human Hb, and few detect, in addition, the Hb/Hp complex. The advantages of testing both Hb and Hb/Hp complex are obvious, and have been discussed in detail in two recent communications (9, 10) as well as in our previous meta-analysis (3, 4). In the previous studies for Hb and Hb/Hp (CV), VA and AA reading modes were reported separately (9, 10). For the AA mode, the Quick Test Reader (QTR) is needed. QTR is a mobile device for quantitative evaluation of Lateral Flow Assays and the protocol of this instrument has been previously described in detail (9, 12).

Vasilyev et al. (10) and Guimaraes et al. (9) have performed a head-to-head comparison study with SENSA and CV in two independent CRC screening settings. Both studies were concordant in that the characteristics of the FIT (CV) are superior to those of gFOBT (SENSA) as a screening tool for CRC (9, 10). In the present study, we compared the diagnostic accuracy of the two reading modes, using proximal versus distal CRC endpoint in a screening setting. In proximal CRC endpoint, the overall Se of the VA reading was only slightly inferior to that of the AA reading mode. However, the pooled Sp of the AA reading in proximal CRC endpoint, was significantly higher than that of the VA reading mode. Until present, three comprehensive reviews and meta-analyses have been published, where the accuracy of FOBTs was compared in diagnosis of proximal and distal CRCs (6–8). Unfortunately, however, the new-generation ColonView® quick test was not included in these analyses, in part due to the more recent launch of the CV test. Thus, in 2011, Haug et al. (6) reviewed the published screening studies conducted by FOBTs (both FIT and/or guaiac-based) in average-risk adult colonoscopy patients, comparing the test Se for proximal versus distal colorectal neoplasia. Altogether, 7 studies were found eligible. In most of these studies, Se of FOBTs for advanced neoplasia was higher in the distal than in the proximal colon (6). The authors, concluded, however, that the available literature is scarce and not entirely consistent. This review did not include HSROC analysis of the diagnostic performance of the FOBTs (6).

In 2016, Hirai et al. (7) reported a meta-analysis assessing the diagnostic accuracy of FOBTs stratified by the anatomical location of CRC. In their meta-analysis, 13 eligible studies reported the diagnostic performance of FOBTs (with the AUC values) in diagnosis of proximal and distal CRC (7). The pooled Se was 90% for proximal and 94% for the distal CRC (p=0.014). The results of these two meta-analyses (6, 7) are fully consonant with the results of the present analysis, where the CV test proved to be more accurate in detecting distal than proximal CRC. This is despite the fact that the CV test includes the Hb/Hp complex, which has been previously shown to be highly accurate in detection of proximal CRC, far exceeding the accuracy of the Hb component (9, 10). The most recent (in 2019) of the three meta-analysis by Lu et al. (8) reviewed available FOBT studies; however, failed to disclose any significant difference in the diagnostic accuracy of the FOBTs for CRC located in the distal versus proximal colon.

Irrespective of the reading mode of the CV test used (AA or VA) or whether Hb or Hb/Hp complex was analyzed, the diagnostic accuracy of the CV test in the detection of CRC in the proximal colon was inferior to that of the CRC in the distal colon. This observation has important implications in the practice of organized CRC screening. In reality, fecal occult blood derived from the tumors located in the proximal colon, might be missed more easily than the blood from distal CRC lesions. The CV test including the Hb/Hp complex seems to increase the likelihood of detecting FOB from the proximal lesions (9, 10). Another issue is to increase the number of samples. Because of the intermittent bleeding (and its longer passage) from the proximal CRC, multiple samples collected on several consecutive days could probably increase the likelihood of detecting the bleeding, thus increasing the diagnostic performance of the FOBT. This is, indeed, the case with the CV test, as shown by the post-hoc analysis of the data of the recently published study (10); increasing the number of samples from 1 to 3 led to parallel increase in test sensitivity (for all endpoints), reaching 100% for the CRC endpoint (unpublished).

These data are consistent with the results reported by van Roon et al. (2011) (13), who conducted a population-based trial to determine attendance and diagnostic performance of 1- and 2-sample FIT screening in CRC. The detection rates for advanced neoplasia were 3.1% in the 1-sample group and 4.1% in the 2-sample group (at least 1 positive test) implicating that two-sample FIT screening was associated with a higher detection rate of advanced neoplasia compared to 1-sample iFOBT screening (13). However, concerns might arise of the endoscopy resources and screening compliance, and therefore, further studies on cost-effectiveness need to be performed (13).

HSROC analysis has become a convenient approach to evaluate the diagnostic performance of various diagnostic tests (14–22). When applied to the present setting, HSROC curve for the AA reading mode in proximal CRC diagnosis shows a reasonably high AUC value, which is significantly higher than that for VA reading in diagnosis of proximal CRC. However, for the distal CRC endpoint, the diagnostic accuracy of both AA and VA reading is clearly superior to the diagnostic accuracy for the proximal CRC endpoint. As confirmed in a recent meta-analysis, these outstanding performance indicators of the CV favourably compete with the other FIT tests on the market (4).

Conclusion

The present study confirms the applicability of the ColonView quick test (a new-generation FIT) in CRC screening. The AA reading mode showed significantly better diagnostic accuracy as compared to the VA reading (or SENSA), in detecting proximal CRC. When stratified by the cancer site (proximal vs. distal), the diagnostic performance of both the AA and VA reading modes is clearly superior for cancers in the distal site as compared with the proximal cancers. As determined from the results of a recent meta-analysis (4), these performance indicators of the CV test (both VA and AA) favourably compete with the most advanced FIT tests on the market.

Acknowledgements

The study was funded by the Päivikki and Sakari Sohlberg Foundation.

Footnotes

  • ↵* These Authors contributed equally to this study.

  • Authors’ Contributions

    All Authors contributed to the collection and analysis of data, drafting and revising the manuscript, read and approved the final article.

  • Conflicts of Interest

    Tapani Tiusanen, Ph.D., is employee of Biohit Oyj, Helsinki, Finland. The other Authors report no conflicts of interest or financial ties to disclose.

  • Received November 28, 2021.
  • Revision received January 26, 2022.
  • Accepted February 16, 2022.
  • Copyright © 2022 The Author(s). Published by the International Institute of Anticancer Research.

This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY-NC-ND) 4.0 international license (https://creativecommons.org/licenses/by-nc-nd/4.0).

References

  1. ↵
    1. Bray F,
    2. Ferlay J,
    3. Soerjomataram I,
    4. Siegel RL,
    5. Torre LA and
    6. Jemal A
    : Global cancer statistics 2018: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 68(6): 394-424, 2018. PMID: 30207593. DOI: 10.3322/caac.21492
    OpenUrlCrossRefPubMed
  2. ↵
    1. Segnan N,
    2. Patrick J and
    3. von Karsa L
    1. Halloran S,
    2. Launoy G and
    3. Zappa M
    : Faecal occult blood testing. In: European guidelines for quality assurance in colorectal cancer screening and diagnosis. Segnan N, Patrick J and von Karsa L (eds.). Luxemburg, Publications Office of the European Union, pp. 103-144, 2010.
  3. ↵
    1. Meklin J,
    2. Syrjänen K and
    3. Eskelinen M
    : Colorectal cancer screening with traditional and new-generation fecal immunochemical tests: a critical review of fecal occult blood tests. Anticancer Res 40(2): 575-581, 2020. PMID: 32014898. DOI: 10.21873/anticanres.13987
    OpenUrlAbstract/FREE Full Text
  4. ↵
    1. Meklin J,
    2. Syrjänen K and
    3. Eskelinen M
    : Fecal occult blood tests in colorectal cancer screening: systematic review and meta-analysis of traditional and new-generation fecal immunochemical tests. Anticancer Res 40(7): 3591-3604, 2020. PMID: 32620599. DOI: 10.21873/anticanres.14349
    OpenUrlAbstract/FREE Full Text
    1. Suovaniemi O
    : Immunoassay for fecal human hemoglobin. Available at: https://patents.google.com/patent/US4427769 [Last accessed on January 26, 2022]
  5. ↵
    1. Haug U,
    2. Knudsen AB,
    3. Brenner H and
    4. Kuntz KM
    : Is fecal occult blood testing more sensitive for left- versus right-sided colorectal neoplasia? A systematic literature review. Expert Rev Mol Diagn 11(6): 605-616, 2011. PMID: 21745014. DOI: 10.1586/erm.11.41
    OpenUrlCrossRefPubMed
  6. ↵
    1. Hirai HW,
    2. Tsoi KK,
    3. Chan JY,
    4. Wong SH,
    5. Ching JY,
    6. Wong MC,
    7. Wu JC,
    8. Chan FK,
    9. Sung JJ and
    10. Ng SC
    : Systematic review with meta-analysis: faecal occult blood tests show lower colorectal cancer detection rates in the proximal colon in colonoscopy-verified diagnostic studies. Aliment Pharmacol Ther 43(7): 755-764, 2016. PMID: 26858128. DOI: 10.1111/apt.13556
    OpenUrlCrossRefPubMed
  7. ↵
    1. Lu M,
    2. Luo X,
    3. Li N,
    4. Chen H and
    5. Dai M
    : Diagnostic accuracy of fecal occult blood tests for detecting proximal versus distal colorectal neoplasia: a systematic review and meta-analysis. Clin Epidemiol 11: 943-954, 2019. PMID: 31695506. DOI: 10.2147/CLEP.S213677
    OpenUrlCrossRefPubMed
  8. ↵
    1. Guimarães DP,
    2. Fregnani JH,
    3. Reis RM,
    4. Taveira LN,
    5. Scapulatempo-Neto C,
    6. Matsushita M,
    7. Silva SRM,
    8. Oliveira CZ,
    9. Longatto-Filho A,
    10. Eklund C,
    11. Paloheimo L,
    12. Mauad E,
    13. Suovaniemi O and
    14. Syrjänen K
    : Comparison of a new-generation fecal immunochemical test (FIT) with guaiac fecal occult blood test (gFOBT) in detecting colorectal neoplasia among colonoscopy-referral patients. Anticancer Res 39(1): 261-269, 2019. PMID: 30591467. DOI: 10.21873/anticanres.13106
    OpenUrlAbstract/FREE Full Text
  9. ↵
    1. Vasilyev S,
    2. Smirnova E,
    3. Popov D,
    4. Semenov A,
    5. Eklund C,
    6. Hendolin P,
    7. Paloheimo L and
    8. Syrjänen K
    : A new-generation fecal immunochemical test (FIT) is superior to quaiac-based test in detecting colorectal neoplasia among colonoscopy referral patients. Anticancer Res 35(5): 2873-2880, 2015. PMID: 25964570.
    OpenUrlAbstract/FREE Full Text
  10. ↵
    1. Songster CL,
    2. Barrows GH and
    3. Jarrett DD
    : Immunochemical detection of fecal occult blood—the fecal smear punch-disc test: a new non-invasive screening test for colorectal cancer. Cancer 45(5 Suppl): 1099-1102, 1980. PMID: 6965607. DOI: 10.1002/1097-0142(19800315)45:5+<1099::aid-cncr2820451312>3.0.co;2-t
    OpenUrlCrossRefPubMed
  11. ↵
    ColonView Quick Test. Available at: https://www.biohithealthcare.com/en/products/diagnostic-tests/colonview-quick-test/ [Last accessed on February 16, 2022]
  12. ↵
    1. van Roon AH,
    2. Wilschut JA,
    3. Hol L,
    4. van Ballegooijen M,
    5. Reijerink JC,
    6. ‘t Mannetje H,
    7. Kranenburg LJ,
    8. Biermann K,
    9. van Vuuren AJ,
    10. Francke J,
    11. van der Togt AC,
    12. Habbema DJ,
    13. van Leerdam ME and
    14. Kuipers EJ
    : Diagnostic yield improves with collection of 2 samples in fecal immunochemical test screening without affecting attendance. Clin Gastroenterol Hepatol 9(4): 333-339, 2011. PMID: 21185397. DOI: 10.1016/j.cgh.2010.12.012
    OpenUrlCrossRefPubMed
  13. ↵
    1. Meklin J,
    2. Eskelinen M,
    3. Syrjänen K and
    4. Eskelinen M
    : Leucocyte count does not improve the diagnostic performance of a diagnostic score (DS) in distinguishing acute appendicitis (AA) from nonspecific abdominal pain (NSAP). In Vivo 34(6): 3327-3339, 2020. PMID: 33144440. DOI: 10.21873/invivo.12171
    OpenUrlAbstract/FREE Full Text
    1. Meklin J,
    2. Eskelinen M,
    3. Syrjänen K and
    4. Eskelinen M
    : Gender-specific performance of a diagnostic score in acute appendicitis. In Vivo 34(6): 3687-3703, 2020. PMID: 33144486. DOI: 10.21873/invivo.12217
    OpenUrlAbstract/FREE Full Text
    1. Eskelinen M,
    2. Meklin J,
    3. Syrjänen K and
    4. Eskelinen M
    : Performance of a diagnostic score in confirming acute cholecystitis among patients with acute abdominal pain. Anticancer Res 40(12): 6947-6956, 2020. PMID: 33288589. DOI: 10.21873/anticanres.14719
    OpenUrlAbstract/FREE Full Text
    1. Eskelinen M,
    2. Meklin J,
    3. Syrjänen K and
    4. Eskelinen M
    : Pediatric acute appendicitis score in children with acute abdominal pain (AAP). Anticancer Res 41(1): 297-306, 2021. PMID: 33419824. DOI: 10.21873/anticanres.14776
    OpenUrlAbstract/FREE Full Text
    1. Eskelinen M,
    2. Meklin J,
    3. Syrjänen K and
    4. Eskelinen M
    : A diagnostic score (DS) is a powerful tool in diagnosis of acute appendicitis in elderly patients with acute abdominal pain. Anticancer Res 41(3): 1459-1469, 2021. PMID: 33788738. DOI: 10.21873/anticanres.14904
    OpenUrlAbstract/FREE Full Text
    1. Eskelinen M,
    2. Meklin J,
    3. Syrjänen K and
    4. Eskelinen M
    : A Diagnostic score for acute small bowel obstruction. Anticancer Res 41(4): 1959-1970, 2021. PMID: 33813402. DOI: 10.21873/anticanres.14963
    OpenUrlAbstract/FREE Full Text
    1. Eskelinen M,
    2. Meklin J,
    3. Syrjänen K and
    4. Eskelinen M
    : A Diagnostic score for reliable confirmation of acute renal colic among patients with acute abdominal pain. Anticancer Res 41(6): 3045-3054, 2021. PMID: 34083296. DOI: 10.21873/anticanres.15087
    OpenUrlAbstract/FREE Full Text
    1. Meklin J,
    2. Eskelinen M,
    3. Guimaraes DP,
    4. Selander T,
    5. Inkinen J,
    6. Tiusanen T,
    7. Syrjänen K and
    8. Eskelinen M
    : The new generation immunochemical test for fecal occult blood (ColonView Quick Test) shows a high diagnostic accuracy in colorectal cancer detection. Anticancer Res 41(10): 5071-5079, 2021. PMID: 34593457. DOI: 10.21873/anticanres.15323
    OpenUrlAbstract/FREE Full Text
  14. ↵
    1. Meklin J,
    2. Eskelinen M,
    3. Guimaraes DP,
    4. Selander T,
    5. Tiusanen T,
    6. Syrjänen K and
    7. Eskelinen M
    : The automatically analyzed (AA) ColonView (CV) quick test for fecal occult blood shows higher diagnostic accuracy in detection of colorectal adenoma than visually analyzed tests. Anticancer Res 41(11): 5517-5525, 2021. PMID: 34732422. DOI: 10.21873/anticanres.15365
    OpenUrlAbstract/FREE Full Text
PreviousNext
Back to top

In this issue

Anticancer Research
Vol. 42, Issue 4
April 2022
  • Table of Contents
  • Table of Contents (PDF)
  • Index by author
  • Back Matter (PDF)
  • Ed Board (PDF)
  • Front Matter (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Anticancer Research.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The ColonView (CV) Quick Test for Fecal Occult Blood Shows Significantly Higher Diagnostic Accuracy in Detecting Distal than Proximal Colorectal Cancer
(Your Name) has sent you a message from Anticancer Research
(Your Name) thought you would like to see the Anticancer Research web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
4 + 11 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
The ColonView (CV) Quick Test for Fecal Occult Blood Shows Significantly Higher Diagnostic Accuracy in Detecting Distal than Proximal Colorectal Cancer
MAARET ESKELINEN, JANNICA MEKLIN, DENISE PEIXOTO GUIMARÃES, TUOMAS SELANDER, TAPANI TIUSANEN, KARI SYRJÄNEN, MATTI ESKELINEN
Anticancer Research Apr 2022, 42 (4) 1879-1891; DOI: 10.21873/anticanres.15664

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Reprints and Permissions
Share
The ColonView (CV) Quick Test for Fecal Occult Blood Shows Significantly Higher Diagnostic Accuracy in Detecting Distal than Proximal Colorectal Cancer
MAARET ESKELINEN, JANNICA MEKLIN, DENISE PEIXOTO GUIMARÃES, TUOMAS SELANDER, TAPANI TIUSANEN, KARI SYRJÄNEN, MATTI ESKELINEN
Anticancer Research Apr 2022, 42 (4) 1879-1891; DOI: 10.21873/anticanres.15664
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Patients and Methods
    • Results
    • Discussion
    • Conclusion
    • Acknowledgements
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

Cited By...

  • Four Different Artificial Intelligence Models Versus Logistic Regression to Enhance the Diagnostic Accuracy of Fecal Immunochemical Test in the Detection of Colorectal Carcinoma in a Screening Setting
  • Colorectal Cancer Screening by Fecal Immunochemical Tests (FIT): Considerations on Sampling and Markers (Hb and Hb/Hp Complex) of Fecal Occult Blood (FOB)
  • The Diagnostic Accuracy (DA) of ColonView Fecal Immunochemical Test (FIT) in Detecting Colorectal Adenoma (CRA) Can Be Improved by the Diagnostic Models (DM) that Include Triage and Risk Features of CRA
  • Triage Process at Endoscopy With ColonView Fecal Immunochemical Test (FIT) Will Enhance Diagnostic Accuracy (DA) of Colorectal Cancer Screening
  • Fecal Immunochemical Test (FIT) in Triage of Bleed-positive (Crab+) and Bleed-negative Colorectal Adenoma (Crab-) Patients in Colorectal Neoplasia Screening
  • Diagnostic Accuracy of Fecal Immunochemical Test (FIT) in Bleed-positive and Bleed-negative Colorectal Cancer (CRC) Among a Cohort of 5,090 Subjects who Participated in the Colorectal Neoplasia (CRN) Screening in Brazil
  • Site-specific Performance of ColonView (CV) Fecal Immunochemical Test (FIT) With Differences Between Proximal and Distal Colorectal Adenoma
  • Google Scholar

More in this TOC Section

  • A Reminder App for Optimizing Bladder Filling During Radiotherapy for Prostate Cancer: A Pre-study in Healthy Volunteers
  • Timing and Risk Factors for Hyperglycemia Associated With Anamorelin Administration
  • Identification of Risk Factors for the Local Recurrence of Hepatocellular Carcinoma Post-radiofrequency Ablation
Show more Clinical Studies

Keywords

  • fecal immunochemical test
  • FIT
  • colorectal cancer screening
  • ROC
  • proximal colon
  • distal colon
Anticancer Research

© 2026 Anticancer Research

Powered by HighWire