Skip to main content

Main menu

  • Home
  • Current Issue
  • Archive
  • Info for
    • Authors
    • Subscribers
    • Advertisers
    • Editorial Board
  • Other Publications
    • In Vivo
    • Cancer Genomics & Proteomics
    • Cancer Diagnosis & Prognosis
  • More
    • IIAR
    • Conferences
    • 2008 Nobel Laureates
  • About Us
    • General Policy
    • Contact
  • Other Publications
    • Anticancer Research
    • In Vivo
    • Cancer Genomics & Proteomics

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Anticancer Research
  • Other Publications
    • Anticancer Research
    • In Vivo
    • Cancer Genomics & Proteomics
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Anticancer Research

Advanced Search

  • Home
  • Current Issue
  • Archive
  • Info for
    • Authors
    • Subscribers
    • Advertisers
    • Editorial Board
  • Other Publications
    • In Vivo
    • Cancer Genomics & Proteomics
    • Cancer Diagnosis & Prognosis
  • More
    • IIAR
    • Conferences
    • 2008 Nobel Laureates
  • About Us
    • General Policy
    • Contact
  • Visit us on Facebook
  • Follow us on Linkedin
Research ArticleExperimental Studies

Feasibility of a Tungsten Rubber Grid Collimator for Electron Grid Therapy

KENTA KIJIMA, ANCHALI KRISANACHINDA, MIKOTO TAMURA, YASUMASA NISHIMURA and HAJIME MONZEN
Anticancer Research June 2019, 39 (6) 2799-2804; DOI: https://doi.org/10.21873/anticanres.13407
KENTA KIJIMA
1Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
ANCHALI KRISANACHINDA
2Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
MIKOTO TAMURA
1Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
YASUMASA NISHIMURA
3Department of Radiation Oncology, Faculty of Medicine, Kindai University, Osaka, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
HAJIME MONZEN
1Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: hmon@med.kindai.ac.jp
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

This article has a correction. Please see:

  • Errata - February 01, 2020

Abstract

Background/Aim: Spatially fractionated radiotherapy (grid therapy) can control some bulky tumors which is challenging for conventional radiotherapy. This study aimed to investigate whether a novel tungsten contained rubber (TCR) grid collimator can be employed in electron grid therapy. Materials and Methods: The TCR grid collimator placed on a solid water phantom, and percentage depth doses (PDDs) and lateral dose profiles were measured for 9 MeV electron beam with Gafchromic EBT3 films. At the lateral dose profile, the ratios of the dose in the areas with and without shielding (valley-to-peak ratios) were evaluated. Results: The dmax values with the 1, 2 and 3 mm TCR grid collimators were 1.2, 1.1 and 0.7 cm, respectively, while the valley-to-peak ratios at each dmax were 0.566, 0.412 and 0.293, respectively. Conclusion: Only the 2 mm TCR grid collimator had adequate dosimetric features compared to the conventional grid collimator and could be substituted.

  • Tungsten-contained rubber
  • electron grid therapy
  • bulky superficial tumor

Spatially fractionated radiotherapy (grid therapy) was introduced by Alban Kohler in 1909 for treating deep-seated tumors (1). It was possible to treat without the extensive damage of skin and subcutaneous tissue occurring following irradiation through a special grid collimator with small circular or square apertures. Subsequently, grid therapy was poorly evaluated and hardly ever used until the 1930s. Following the work of Jolles et al. (2) during the orthovoltage era, the usefulness of the grid therapy was shown by Mohiuddin et al. in the late 20th and early 21st century again (3-5). The combination of grid therapy, irradiating a dose of 15 Gy or higher, and additional external beam resulted in higher response rates than conventional radiotherapy alone. In addition, Ha et al. showed the feasibility of mega-voltage photon grid therapy (4-6), which is able to create a grid of appropriate size and pattern using multileaf collimator. It could treat deep-seated tumors easier than grid therapy using cerrobend (Cerro Metal Products, Bellefonte, PA, USA) grid collimator, although a longer delivery time was needed (7).

Photon grid therapy is an excellent treatment, however electron grid therapy is superior to the photon grid therapy for large and superficial tumors where critical radiosensitive structures are present behind the tumor in the path of the photon beams (7), since the dose of the electron beam rapidly attenuates after passing through a medium (8-10). Tamura et al. have shown that the Tungsten Functional Paper (TFP) could be used in electron grid therapy, having both radiation shielding ability and paper flexibility properties (11-16), instead of cerrobend by Monte Carlo simulation (10). In a previous study, tungsten-contained rubber (TCR) (B050TE®, Hayakawa Rubber Co., Ltd. Hiroshima, Japan) was developed and displayed adequate shielding efficiency against electron beams (17). The cerrobend has odors and is possibly toxic to the human body, due to the vapor cloud of heavy metals during processing and may have harmful effects on the environment (18-20). On the other hand, TCR is a non-toxic, shielding material that is good for the human body and environment due to its ecofriendly products (lead free), has high density and is waterproof (16, 17). In addition, owing to its flexibility, TCR can adapt and acquire various conformations such as shoulder and belly (17).

The aim of this study was to show the feasibility of TCR grid collimators in electron grid therapy by a phantom study. The dosimetric characteristics and their possible clinical applications were investigated.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table I.

Physical properties of tungsten-contained rubber collimator.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table II.

Measured values of depth of dmax, d90 and d80 from the PDDs for the grid-collimated electron beams with TCR, cerrobend (7) and TFP (10) grid collimators.

Materials and Methods

The dosimetric characteristics of the TCR grid collimators in electron grid therapy were evaluated with phantom experiments. Table I shows the physical properties of TCR. The elemental composition of TCR (mol%) is H: 1.0%, C: 6.5%, O: 0.5%, W: 90.0% and others: 2.0%. TCR grid collimator was created according to previous studies (7, 10), the aperture diameter of the holes were 2.5 cm and the center-to-center spacing of the holes were 3.0 cm. The schema of the TCR grid collimator is shown in Figure 1.

The geometry for the measurements of the depth and lateral dose profiles with the TCR grid collimator is shown in Figure 2. An electron beam of a nominal energy of 9 MeV was generated with a linear accelerator (Clinac 21EX®, Varian Medical Systems, Palo Alto, CA, USA) with a 20×20 cm2 electron applicator. Each measurement was taken with 200 MU irradiation. The electron beams were collimated with the TCR grid collimator placed on the surface of a virtual water phantom (MedTec Inc., Orange City, IA, USA). The thicknesses of the TCR grid collimators were 1, 2 and 3 mm. The percentage depth dose (PDD) at the center of the beam axis and the lateral dose profile (source-to-surface distance=100 cm) for the grid-collimated electron beams were measured with Gafchromic EBT3 films (ISP, Wayne, NJ, USA). The films were arranged parallel to the beam's central axis for PDD and lateral dose profile measurements.

First, the depths of the maximum dose (dmax), 90% dose (d90) and 80% dose (d80) in the virtual water phantom were evaluated from PDD data. Then, the lateral dose profiles were evaluated at dmax, d90 and d80 with valley-to-peak ratios, defined as dose ratios of the blocked to the open areas. The valley-to-peak ratios were calculated from the ratios of the average values at the center of four blocked areas and five open areas (10).

Figure 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 1.

Schema of the TCR grid collimator. The aperture diameter was 2.50 cm, the center-to-center spacing of holes was at 3.00 cm intervals and the blocked area was 80%.

Figure 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 2.

Schematic diagram of the experimental setup for film dosimetry in virtual water phantom. Films were arranged parallel to the beam's central axis.

Results

The PDD curves for the grid-collimated electron beams at each thickness of the TCR grid collimator are shown in Figure 3. From the PDD curves, the depths of dmax, d90 and d80 at each thickness of the TCR grid collimator are shown in Table II. The dmax was shifted toward the surface with increasing thickness of the TCR grid collimator. The PDD curves with the TCR grid collimator were shifted toward the surface compared to that without the TCR grid collimator.

Figure 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 3.

PDDs for the grid-collimated electron beams at 9 MeV electron beams at each thickness of the TCR grid collimator at the center of an open area in the position of the center opening in the TCR grid collimator. The PDD curves were normalized by the value of each dmax.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table III.

Measured values of peaks, valleys and valley-to-peak ratios at dmax, d90 and d80 in lateral dose profiles for the grid-collimated electron beams with TCR, cerrobend (7) and TFP (10) grid collimators.

Lateral dose profiles for the grid-collimated electron beams at each TCR grid collimator thickness at dmax, d90 and d80 are shown in Figure 4. The mean relative doses to the open areas (as peak) and the blocked areas (as valley) and valley-to-peak ratios at dmax, d90 and d80 at each TCR grid collimator thickness are shown in Table III. The valley-to-peak ratios were increased with increasing depth, and decreased with increasing grid collimator thickness because of shielding intensity. The low valley-to-peak ratios show the large difference between the valley and peak dose values, which mean high sparing of normal tissue (10). The TCR grid collimator thickness affected the sparing effect and it was decreased with depth increasing. Therefore, the relation between the effect of sparing normal tissue and treatment range such as d90 or d80 was a tradeoff (10).

Figure 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 4.

Lateral dose profiles for the grid-collimated electron beams at 9 MeV electron beams with TCR grid collimator of 1 mm, 2 mm and 3 mm thickness in depths of dmax, d90 and d80. The profiles were normalized by the central axis measurement value at the dmax corresponding to TCR grid collimator thickness.

As shown in Tables II and III, only the 2 mm TCR grid collimator achieved the equivalent dosimetric properties of a 5.2 mm TFP grid collimator (10) for PDD and lateral dose profiles at dmax, d90 and d80. In addition, it also achieved the dosimetric characteristics of a cerrobend grid collimator for lateral dose profile, although the PDD curve with the TCR grid collimator was shifted to the surface compared to that with the cerrobend grid collimator, which had the same result as the TFP grid collimator.

Discussion

In this study, we showed the TCR grid collimator could be employed to the electron grid therapy by a phantom study. The 2 mm TCR grid collimator had almost identical dosimetric characteristics as grid collimators compared to 1.4 cm cerrobend or 5.2 mm TFP (7, 10).

The result of PDD shows that the depths of dmax, d90 and d80 were shifted toward the surface as the thickness of the TCR grid collimator was increasing.

The valley-to-peak ratios were changed with measurement depth, and their maximum values were at dmax. It has been shown that valley-to-peak ratios, beam spacing and valley doses are related to radiobiological response in animal experiments (21). Wide beam spacing, low valley-to-peak ratios and low valley doses have been related to healthy tissue conservation (21). In addition, high valley-to-peak ratios without high valley doses and cold spots have been related to tumor control (21, 22). Based on that, the 2 mm TCR grid collimator was the most suitable because the peak doses, valley doses and valley-to-peak ratios were similar to previous studies (7, 10). To reduce the dose of irradiation field's penumbra of 2 mm TCR grid collimator, an additional shield could be placed up-stream of TCR grid collimator as has been shown by Tamura et al. (10).

Mohiuddin et al. have shown the usefulness of photon grid therapy for treatment of sarcoma (total response rate of 83%) and squamous cell carcinoma (total response rate of 94%) (4). On the other hand, photon grid therapy has not adapted to treat superficial cancers like melanoma (total response rate of 50%) (4). Electron grid therapy was advantageous against superficial cancers as described by Meigooni et al. (7) and Tamura et al. (10). Additionally, the TCR gird collimator was better adapted to put on the patient's body surface than the TFP grid collimator owing to its flexibility, waterproof property and moderate weight. From these reasons, the TCR grid collimator was expected as excellent grid collimator to treat superficial cancers with electron grid therapy rather than cerrobend or TFP grid collimator.

Conclusion

Only the 2 mm TCR grid collimator, laying simply on a patient's skin, had adequate dosimetric characteristics with conventional grid collimators in electron grid therapy. The TCR grid collimator has the features of flexibility, waterproof and moderate weight, therefore it is expected to be used for electron grid therapy instead of the conventional grid collimator.

Acknowledgements

The Authors acknowledge with thanks the staff of Division of Radiation Therapy, King Chulalongkorn Memorial Hospital, for providing the suitable equipment to validate the application of the TCR grid collimator in experiments.

This work was supported partly by JSPS KAKENHI grant numbers 16K09027, 19K17213 and 19K08211.

Footnotes

  • Authors' Contributions

    KK, AK, MT and HM designed the study and the analysis. KK and AK were responsible for data collection and data management. KK, MT and HM performed data analysis. All Authors collaborated on writing the manuscript, read and approved the final manuscript.

  • Conflicts of Interest

    Hajime Monzen received a research donation from Hayakawa rubber Co., LTD.

  • Received April 17, 2019.
  • Revision received May 14, 2019.
  • Accepted May 15, 2019.
  • Copyright© 2019, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved

References

  1. ↵
    1. Laissue JA,
    2. Blattmann H,
    3. Slatkin DN
    : Alban Köhler (1874-1947): Erfinder der Gittertherapie. Z Med Phys 22: 90-99, 2012. DOI: 10.1016/j.zemedi.2011.07.002
    OpenUrlPubMed
  2. ↵
    1. Jolles B
    : The study of connective-tissue reaction to radiation. The sieve or chess method. Br J Cancer 3: 27-31, 1949. PMID: 18140404. DOI: 10.1038/bjc.1949.3
    OpenUrlCrossRefPubMed
  3. ↵
    1. Mohiuddin M,
    2. Stevens JH,
    3. Reiff JE,
    4. Huq MS,
    5. Suntharalingam N
    : Spatially fractionated (GRID) radiation for palliative treatment of advanced cancer. Radiat Oncol Investig 4: 41-47, 1996. DOI: 10.1002/(SICI)1520-6823(1996)4: 1<41:: AID-ROI7>3.0.CO;2-M
    OpenUrlCrossRef
  4. ↵
    1. Mohiuddin M,
    2. Fujita M,
    3. Regine WF,
    4. Megooni AS,
    5. Ibbott GS,
    6. Ahmed MM
    : High-dose spatially-fractionated radiation (GRID): a new paradigm in the management of advanced cancers. Int J Radiat Oncol 45: 721-727, 1999. PMID: 10524428. DOI: 10.1016/S0360-3016(99)00170-4
    OpenUrlCrossRefPubMed
  5. ↵
    1. Neuner G,
    2. Mohiuddin MM,
    3. Vander Walde N,
    4. Goloubeva O,
    5. Ha J,
    6. Yu CX,
    7. Regine WF
    : High-dose spatially fractionated GRID radiation therapy (SFGRT): A comparison of treatment outcomes with Cerrobend vs. MLC SFGRT. Int J Radiat Oncol Biol Phys 82: 1642-1649, 2012. PMID: 21531514. DOI: 10.1016/j.ijrobp.2011.01.065
    OpenUrlPubMed
  6. ↵
    1. Ha JK,
    2. Zhang G,
    3. Naqvi SA,
    4. Regine WF,
    5. Yu CX
    : Feasibility of delivering grid therapy using a multileaf collimator. Med Phys 33: 76-82, 2006. PMID: 16485412. DOI: 10.1118/1.2140116
    OpenUrlPubMed
  7. ↵
    1. Meigooni AS,
    2. Parker SA,
    3. Zheng J,
    4. Kalbaugh KJ,
    5. Regine WF,
    6. Mohiuddin M
    : Dosimetric characteristics with spatial fractionation using electron grid therapy. Med Dosim 27: 37-42, 2002. PMID: 12019964. DOI: 10.1016/S0958-3947(02)00086-9
    OpenUrlCrossRefPubMed
  8. ↵
    1. Khan FM,
    2. Gibbons JP
    : Khan's The Physics of Radiation Therapy. 5th ed. Philadelphia, United States, Lippincott Williams and Wilkins, 2014.
    1. Lin KH,
    2. Huang CY,
    3. Lin JP,
    4. Chu TC
    : Surface dose with grids in electron beam radiation therapy. Appl Radiat Isot 56: 477-484, 2002. PMID: 11922415. DOI: 10.1016/S0969-8043(01)00249-4
    OpenUrlPubMed
  9. ↵
    1. Tamura M,
    2. Monzen H,
    3. Kubo K,
    4. Hirata M,
    5. Nishimura Y
    : Feasibility of tungsten functional paper in electron grid therapy: A Monte Carlo study. Phys Med Biol 62: 878-889, 2017. DOI: 10.1088/1361-6560/62/3/878
    OpenUrl
  10. ↵
    1. Monzen H,
    2. Tamura M,
    3. Hanaoka K,
    4. Matsumoto K,
    5. Hayakawa M
    : Development and application of radiation shielding paper. Ionaizing Radiat 41: 139-143, 2016.
    OpenUrl
    1. Monzen H,
    2. Kanno I,
    3. Fujimoto T,
    4. Hiraoka M
    : Estimation of the shielding ability of a tungsten functional paper for diagnostic x-rays and gamma rays. J Appl Clin Med Phys 18: 325-329, 2017. PMID: 28656739. DOI: 10.1002/acm2.12122
    OpenUrl
    1. Monzen H,
    2. Tamura M,
    3. Shimomura K,
    4. Onishi Y,
    5. Nakayama S,
    6. Fujimoto T,
    7. Matsumoto K,
    8. Hanaoka K,
    9. Kamomae T
    : A novel radiation protection device based on tungsten functional paper for application in interventional radiology. J Appl Clin Med Phys 18: 215-220, 2017. PMID: 28422397. DOI: 10.1002/acm2.12083
    OpenUrl
    1. Fujimoto T,
    2. Monzen H,
    3. Nakata M,
    4. Okada T,
    5. Yano S,
    6. Takakura T,
    7. Kuwahara J,
    8. Sasaki M,
    9. Higashimura K,
    10. Hiraoka M
    : Dosimetric shield evaluation with tungsten sheet in 4, 6, and 9MeV electron beams. Phys Medica 30: 838-842, 2014. PMID: 24953537. DOI: 10.1016/j.ejmp.2014.05.009
    OpenUrl
    1. Kamomae T,
    2. Monzen H,
    3. Kawamura M,
    4. Okudaira K,
    5. Nakaya T,
    6. Mukoyama T,
    7. Miyake Y,
    8. Ishihara Y,
    9. Itoh Y,
    10. Naganawa S
    : Dosimetric feasibility of using tungsten-based functional paper for flexible chest wall protectors in intraoperative electron radiotherapy for breast cancer. Phys Med Biol 63: 015006, 2017. PMID: 29083315. DOI: 10.1088/1361-6560/aa96cf
    OpenUrl
  11. ↵
    1. Kosaka H,
    2. Monzen H,
    3. Matsumoto K,
    4. Tamura M,
    5. Nishimura Y
    : Reduction of operator hand exposure in interventional radiology with a novel finger sack using tungsten-containing rubber. Health Phys 116: 625-630, 2019. DOI: 10.1097/HP.0000000000000992
    OpenUrl
  12. ↵
    1. Kijima K,
    2. Monzen H,
    3. Matsumoto K,
    4. Tamura M,
    5. Nishimura Y
    : The shielding ability of novel tungsten rubber against the electron beam for clinical use in radiation therapy. Anticancer Res 38: 3919-3927, 2018. PMID: 29970513. DOI: 10.21873/anticanres.12677
    OpenUrlAbstract/FREE Full Text
  13. ↵
    1. World Health Organization(WHO)
    . Environmental Health Criteria165, inorganic lead., 1995. Available from: http://www.inchem.org/documents/ehc/ehc/ehc165.htm
    1. World Health Organization(WHO)
    . Safety Evaluation of Certain Food Additives and Contaminants, WHO Food Additive Series: 44, 2000. Available from: http://www.inchem.org/documents/jecfa/jecmono/v44jec12.htm
  14. ↵
    1. Rapisarda V,
    2. Ledda C,
    3. Castaing M,
    4. Proietti L,
    5. Ferrante M
    : Potential exposure to carcinogens in low-melting alloys processing. G Ital Med Lav Ergon 35: 73-76, 2013. PMID: 23914599.
    OpenUrl
  15. ↵
    1. Dilmanian FA,
    2. Button TM,
    3. Le Duc G,
    4. Zhong N,
    5. Pena LA,
    6. Smith JAL,
    7. Martinez SR,
    8. Bacarian T,
    9. Tammam J,
    10. Ren B,
    11. Farmer PM,
    12. Kalef-Ezra J,
    13. Micca PL,
    14. Nawrocky MM,
    15. Niederer JA,
    16. Recksiek FP,
    17. Fuchs A,
    18. Rosen EM
    : Response of rat intracranial 9L gliosarcoma to microbeam radiation therapy. Neuro Oncol 4: 26-38, 2002. PMID: 11772430. DOI: 10.1093/neuonc/4.1.26
    OpenUrlCrossRefPubMed
  16. ↵
    1. Regnard P,
    2. Duc G Le,
    3. Bräuer-Krisch E,
    4. Troprès I,
    5. Siegbahn EA,
    6. Kusak A,
    7. Clair C,
    8. Bernard H,
    9. Dallery D,
    10. Laissue JA,
    11. Bravin A
    : Irradiation of intracerebral 9L gliosarcoma by a single array of microplanar x-ray beams from a synchrotron: Balance between curing and sparing. Phys Med Biol 53: 861-878, 2008. DOI: 10.1088/0031-9155/53/4/003
    OpenUrlCrossRefPubMed
PreviousNext
Back to top

In this issue

Anticancer Research: 39 (6)
Anticancer Research
Vol. 39, Issue 6
June 2019
  • Table of Contents
  • Table of Contents (PDF)
  • Index by author
  • Back Matter (PDF)
  • Ed Board (PDF)
  • Front Matter (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Anticancer Research.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Feasibility of a Tungsten Rubber Grid Collimator for Electron Grid Therapy
(Your Name) has sent you a message from Anticancer Research
(Your Name) thought you would like to see the Anticancer Research web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
2 + 18 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Feasibility of a Tungsten Rubber Grid Collimator for Electron Grid Therapy
KENTA KIJIMA, ANCHALI KRISANACHINDA, MIKOTO TAMURA, YASUMASA NISHIMURA, HAJIME MONZEN
Anticancer Research Jun 2019, 39 (6) 2799-2804; DOI: 10.21873/anticanres.13407

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Reprints and Permissions
Share
Feasibility of a Tungsten Rubber Grid Collimator for Electron Grid Therapy
KENTA KIJIMA, ANCHALI KRISANACHINDA, MIKOTO TAMURA, YASUMASA NISHIMURA, HAJIME MONZEN
Anticancer Research Jun 2019, 39 (6) 2799-2804; DOI: 10.21873/anticanres.13407
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Materials and Methods
    • Results
    • Discussion
    • Conclusion
    • Acknowledgements
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • Errata
  • PubMed
  • Google Scholar

Cited By...

  • First Clinical Experience of Tungsten Rubber Electron Adaptive Therapy With Real-time Variable-shape Tungsten Rubber
  • Google Scholar

More in this TOC Section

  • 5-Azacytidine (5-aza) Induces p53-associated Cell Death Through Inhibition of DNA Methyltransferase Activity in Hep3B and HT-29 Cells
  • Prognostic Value of WNT1, NOTCH1, PDGFRβ, and CXCR4 in Oral Squamous Cell Carcinoma
  • Hypoxia-adapted Multiple Myeloma Stem Cells Resist γδ-T-Cell-mediated Killing by Modulating the Mevalonate Pathway
Show more Experimental Studies

Similar Articles

Keywords

  • Tungsten-contained rubber
  • electron grid therapy
  • bulky superficial tumor
Anticancer Research

© 2023 Anticancer Research

Powered by HighWire