Abstract
Background/Aim: To clarify the diagnostic utility of third-look, contrast-enhanced ultrasonography (CEUS) for MRI-detected breast lesions undetectable by unenhanced, second-look ultrasonography (MRI+/US− lesions). Patients and Methods: Clinical stage 0–IIA breast cancer patients who underwent CEUS for incidental MRI+/US− lesions (n=27; cohort 1) and patients with breast lesions detected only by MRI, to be examined by CEUS (n=15; cohort 2), were retrospectively analyzed. Results: Of the 42 MRI+/US− lesions, 23 (55%) were detected by CEUS and then examined by needle biopsy. Pathological examination showed that 10 of these 23 lesions were malignant. None of the 19 lesions undetected by CEUS were found to be histologically malignant or developed malignancy with a median follow-up of 18.5 months. The accuracy, sensitivity, and specificity of CEUS plus needle biopsy were 98%, 91%, and 100%, respectively. Conclusion: Third-look CEUS followed by needle biopsy is useful in the initial diagnosis of MRI+/US− lesions.
- Breast cancer
- magnetic resonance imaging (MRI)
- contrast-enhanced ultrasonography (CEUS)
- needle biopsy
- diagnostic utility
Contrast-enhanced magnetic resonance imaging (MRI) of the breast is a useful tool for precise evaluation of a spreading tumor and plays an important role in the preoperative planning of breast-tissue resection margins. It is reported that preoperative bilateral breast MRI examination helps reveal contralateral breast cancer undetectable by other modalities such as mammography and ultrasonography (US) and contributes to the decrease of contralateral breast cancer recurrence (1), but whether MRI decreases ipsilateral breast cancer recurrence after breast-conserving surgery is controversial (2, 3).
Conventionally, it is pointed out that breast MRI shows a high sensitivity and a low specificity (4). Lesions detected by breast MRI are usually examined by second-look US, with various detection rates (5). Frequency of malignancy of “probably benign lesions” detected by breast MRI (BI-RADS category 3) is reported to be very low but not zero (6). At present, there is no consensus about the management of such lesions, that is, MRI-guided biopsy or regular follow-up with MRI, when such lesions are undetectable by second-look US. On the other hand, MRI-guided biopsy is usually indicated for MRI-detected breast lesions, “suspicious for malignancy” (BI-RADS category 4), and “highly suggestive of malignancy” (BI-RADS category 5) (7, 8). The European Society of Breast Imaging (EUSOBI) guidelines recommend that MRI should be offered by the institutions where MRI-guided biopsy is available or by those that closely connect with such institutions (9). However, MRI-guided biopsy is expensive and time consuming, and thus available only in a limited number of institutes in Japan.
Recently, new methods, such as real-time virtual sonography and contrast-enhanced US (CEUS), using SonoVue® (Bracco S.p.A., Milan, Italy), applied to a limited number of patients (n=10) have been reported to be useful for the diagnosis of suspicious lesions detected by breast MRI (10, 11). CEUS, using perflubutane microbubble (Sonazoid®; Daiichi-Sankyo, Tokyo, Japan), with a mean diameter of 2-3 μm is reported to demonstrate a superiority over unenhanced US in terms of differential diagnosis of breast lesions, with no severe adverse events (12). In the present study, the diagnostic utility of CEUS was retrospectively investigated by Sonazoid® and CEUS-guided needle biopsy for breast MRI lesions undetectable by unenhanced second-look US.
Patients and Methods
Patients. Patients with clinical stage 0-IIA primary breast cancer who underwent third-look, contrast-enhanced US (CEUS) for MRI-detected incidental lesions (BI-RADS category 3–5) which were not detected by unenhanced, second-look US (MRI+/US− lesions) (n=27; cohort 1) and patients with only MRI+/US− breast lesions who underwent third-look CEUS for the index lesions (BI-RADS category 3-4) (n=15; cohort 2) between June 2015 and October 2017 at Osaka University Hospital were retrospectively analyzed in this study. Clinical and radiological findings, including age, clinical stage, symptoms associated with MRI+/US− lesions, positional relationship of MRI+/US− lesions with index tumors, and MRI BI-RADS classifications are shown in Table I. This retrospective observational study was approved by the institutional review board of Osaka University Hospital (approval number 17299).
Breast MRI examination. All MR images were acquired with a 1.5-T or 3.0-T unit in the prone position using a standard dedicated breast array coil at our hospital (n=27) and the other institutes (n=15). For each examination, T1-weighted dynamic contrast MR images were analyzed for this study, including one unenhanced and three contrast-enhanced sequences after a rapid intravenous bolus injection of a gadolinium-containing contrast agent, using a three-dimensional (3D), T1-weighted, fat-saturated gradient echo sequence. MRI-detected lesions were classified into BI-RADS MRI categories (13) by one radiologist at each institution and, in addition, two breast specialists at our hospital.
Contrast-enhanced US and pathological diagnostic procedure. After perflubutane microbubble (Sonazoid®; Daiichi-Sankyo, Tokyo, Japan) was injected intravenously, the suspected breast area with the MRI+/US− lesion was examined by CEUS, using Logiq E9 with XDclear® (GE Healthcare, Tokyo, Japan) (14). When the CEUS detected MRI+/US− lesions, the patients underwent needle biopsy such as US-guided, vacuum-assisted biopsy (VAB; n=21) or fine-needle aspiration cytology (FNAC; n=2) for pathological diagnosis.
Statistical analysis. Diagnostic accuracy of CEUS alone or CEUS followed by needle biopsy for MRI+/US− lesions was evaluated by the following parameters: accuracy, sensitivity, and specificity. Of the 42 lesions, 20 were surgically resected, and final pathological diagnosis, that is, benign or malignant, was made on the surgical specimens, and 22 were not resected but regularly followed up. If the lesions were followed up for more than 12 months with no evidence of malignancy, they were considered benign in the calculation of diagnostic accuracy (15). Regular follow-up was performed by physical examination at 3-6-month intervals, annual mammography, and by US in at least 6 months intervals with or without breast MRI.
JMP® PRO 14 software (SAS Institute Inc., Cary, NC, USA) was used for all statistical analyses. Associations between the two parameters were analyzed using Fisher's exact test. p-Values <0.05 were determined to be statistically significant.
Results
Preoperative diagnosis of MRI-detected lesions. Clinical and radiological findings of the 42 MRI+/US− lesions are shown in Figure 1. CEUS detected 55% (23/42) of these lesions. Of the 42 lesions, 10 (24%) were diagnosed as malignant preoperatively by VAB (n=9) or FNAC (n=1). Finally, following surgery, 3 of the 10 lesions were diagnosed as invasive breast carcinomas and 7 of them as ductal carcinomas in situ (DCIS). Representative cases of MRI+/US− lesions that were detected by third-look CEUS but not by second-look US are shown in Figure 2.
Of the 13 MRI+/US− lesions diagnosed as benign by CEUS-guided biopsy, one was finally diagnosed as DCIS by microdochectomy performed due to the continuing bloody nipple discharge after CEUS-guided VAB. With respect to the other 12 MRI+/US− lesions, none of them were resected but were followed up for a median of 29.5 months (range=13-42 months), without an evidence of malignancy. A comparison between the pathological diagnoses by needle biopsy and surgical specimen of MRI+/US− lesions is shown in Table II.
On the other hand, of the 19 MRI+/US− lesions not detected by CEUS, nine were finally diagnosed as benign after surgery, and 10 were not resected but followed up for a median of 18.5 months (range=14-31 months) with no evidence of malignancy.
Positional relationship of MRI+/US− lesion with index tumor in cohort 1. In cohort 1, all of the MRI+/US− lesions were identified as incidental lesions by preoperative MRI for primary breast cancer. Positional relationship of MRI lesions with index tumor as well as correlation of preoperative with postoperative pathological diagnosis of these incidental lesions are shown in Table III. Five MRI+/US− lesions were in the same quadrant as the index tumor, and six were in a different quadrant from the index tumor; 16 were in the contralateral breast. All of the MRI+/US− lesions diagnosed as malignant by CEUS-guided needle biopsy proved to be malignant by pathological analysis of the surgical specimens.
Identification rate of MRI+/US− lesions by CEUS and their preoperative pathological diagnosis according to MRI BI-RADS category. MRI+/US− lesions included 18 category 3 lesions, 23 category 4 lesions, and one category 5 lesion, according to BI-RADS classification (Table IV). A significantly higher identification rate of the MRI+/US− lesions by CEUS was observed in category 4/5 lesions than in category 3 lesions (79% vs. 22%, p<0.05), and final pathological diagnosis as malignant was significantly more frequent in the category 4/5 lesions than in the category 3 lesions (42% vs. 6%, p<0.05).
Diagnostic accuracy of CEUS alone or CEUS followed by needle biopsy for MRI+/US− lesions. Comparison of CEUS alone and CEUS followed by needle biopsy for MRI+/US− lesions with regard to the final diagnosis is shown in Table V. As for CEUS alone, accuracy, sensitivity, and specificity were 71% (30/42), 100% (11/11), and 61% (19/31), respectively, and, for CEUS plus needle biopsy, they were 98% (41/42), 91% (10/11), and 100% (31/31), respectively.
Discussion
The present study retrospectively investigated the diagnostic utility of third-look CEUS and CEUS-guided needle biopsy for MRI+/US− lesions. As a result, CEUS identified 55% (23 in 42) of the MRI+/US− lesions, and CEUS-guided VAB/FNAC diagnosed 43% of them (10 in 23) as breast cancers. In addition, of these 10 malignant lesions, three (30%) were invasive diseases, consistent with the Tozaki et al. report that MRI-guided needle biopsy for 102 MRI+/US− lesions revealed 34 breast cancers (33%) in which 6 lesions (18%) were invasive cancers (16). The presence of invasive cancer with a significant frequency in the MRI+/US− lesions seemed to indicate a clinical importance of biopsy of such lesions as well as of development of a more convenient method than MRI-guided biopsy such as the CEUS-guided biopsy presented in this study. In addition, in cohort 1, each MRI+/US− lesion that CEUS-guided VAB/FNAB determined to be malignant was located in a different quadrant of the ipsilateral breast from the index tumor, or in the contralateral breast. This result indicates that CEUS followed by needle biopsy contributes to the decision making of operation methods for breast cancer.
In recent years, Nykanen et al. first reported that CEUS detected 50% of a limited number of MRI+/US− breast lesions (n=10) and that CEUS-guided needle biopsy or surgical resection diagnosed 80% of them as malignant (11). The rate of malignancy diagnosed by CEUS-guided biopsy was higher in the Nykanen study than in our study, whereas the identification rate of MRI+/US− lesions was similar between the two studies. This difference in the rate of malignancy may be explained by the fact that their study included only malignant or suspicious (i.e., BI-RADS category 4-5) MRI lesions, whereas our study included BI-RADS category 3 lesions as well as BI-RADS category 4 and 5 lesions. Indeed, in the present study, BI-RADS category 4-5 lesions showed a significantly higher rate of malignancy (42%, 10 in 24) than BI-RADS category 3 lesions (6%, 1 in 18) (p<0.05).
Of the patients whose MRI+/US− lesions were diagnosed as benign by CEUS-guided VAB/FNAC (n=13), one patient underwent additional microdochectomy for the diagnosis of a BI-RADS category 3 lesion, because bloody nipple discharge continued, which may indicate the possibility of a sampling error, and the lesion was finally diagnosed as DCIS. However, all of the remaining 12 MRI+/US− lesions were followed up with no clinical evidence of malignancy. Of the 19 MRI+/US− lesions undetectable by third-look CEUS, nine lesions that were resected and pathologically evaluated, showed no abnormal findings. In addition, the remaining 10 MRI+/US− lesions were followed up with no evidence of clinical malignancy.
Our results demonstrated that CEUS followed by needle biopsy could achieve a high sensitivity (91%) and specificity (100%) in the diagnosis of MRI+/US− lesions, and even CEUS alone could achieve a high sensitivity (100%) with a lower specificity (61%). It is important that none of the CEUS-undetected, MRI+/US− lesions (BI-RADS category 3/4) were found to be malignant, suggesting that such lesions can be followed up without MRI-guided biopsy. Thus, the third-look CEUS for MRI+/US− lesions may appear to contribute to a reduction of the number of MRI-guided biopsies, especially in BI-RADS categories 3–4 MRI+/US− lesions even though the number of patients included in the present study is limited.
Based on the results of the present study, a proposal of the decision tree for the current management of MRI+/US− lesions is shown in Figure 3. For MRI+/US− lesions, third-look CEUS is preferred to MRI-guided biopsy as an initial diagnostic procedure. When CEUS detects MRI+/US− lesions, CEUS-guided needle biopsy should be performed. For MRI+/US− lesions that CEUS-guided biopsy found to be benign, regular follow-up is recommended. If third-look CEUS cannot detect category 4/5 MRI+/US− lesions, MRI-guided needle biopsy should be considered, due to a high probability that the lesions are malignant. The possibility of omission of MRI-guided biopsy for category 4 MRI+/US− lesions being undetected by third-look CEUS should be investigated in a future study. Regular follow-up can be offered for asymptomatic BI-RADS category 3 lesions undetectable by third-look CEUS.
In conclusion, our results suggest that third-look CEUS and CEUS-guided VAB/FNAC are useful diagnostic tools for breast MRI+/US− lesions and are more easily available in most hospitals than MRI-guided VAB. However, CEUS-guided needle biopsy cannot replace the MRI-guided needle biopsy completely, because CEUS could not detect all the MRI+/US− lesions. We propose a decision tree for the current management of MRI+/US− lesions, including CEUS followed by CEUS-guided needle biopsy as an initial diagnostic procedure, which may contribute to decreasing the number of MRI-guided biopsies. To confirm our present findings on the value of CEUS plus needle biopsy, further study, including more patients with a longer follow-up period, is needed.
Acknowledgements
The Authors are grateful to Yukiko Tokuda, MD, of the Department of Diagnostic and Interventional Radiology at Osaka University Hospital, for her contribution to radiological diagnosis. This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Footnotes
Authors' Contributions
TM, SK and SN designed the study, and wrote the initial draft of the manuscript. All Authors have contributed to data collection, analysis and interpretation, and critically reviewed the manuscript.