Skip to main content

Main menu

  • Home
  • Current Issue
  • Archive
  • Info for
    • Authors
    • Editorial Policies
    • Subscribers
    • Advertisers
    • Editorial Board
    • Special Issues
  • Journal Metrics
  • Other Publications
    • In Vivo
    • Cancer Genomics & Proteomics
    • Cancer Diagnosis & Prognosis
  • More
    • IIAR
    • Conferences
    • 2008 Nobel Laureates
  • About Us
    • General Policy
    • Contact
  • Other Publications
    • Anticancer Research
    • In Vivo
    • Cancer Genomics & Proteomics

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Anticancer Research
  • Other Publications
    • Anticancer Research
    • In Vivo
    • Cancer Genomics & Proteomics
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Anticancer Research

Advanced Search

  • Home
  • Current Issue
  • Archive
  • Info for
    • Authors
    • Editorial Policies
    • Subscribers
    • Advertisers
    • Editorial Board
    • Special Issues
  • Journal Metrics
  • Other Publications
    • In Vivo
    • Cancer Genomics & Proteomics
    • Cancer Diagnosis & Prognosis
  • More
    • IIAR
    • Conferences
    • 2008 Nobel Laureates
  • About Us
    • General Policy
    • Contact
  • Visit us on Facebook
  • Follow us on Linkedin
Research ArticleClinical Studies

Assessing the Size of Polyp Phantoms in Tandem Colonoscopies

CARLOS A. RUBIO, CHARLOTTE M. HÖÖG, OLLE BROSTRÖM, JÖRGEN GUSTAVSSON, MATS KARLSSON, PER MORITZ, ROBERT STIG, OLA WIKMAN, LARS MATTSSON and DOMENICO PALLI
Anticancer Research May 2009, 29 (5) 1539-1545;
CARLOS A. RUBIO
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: Carlos.Rubio{at}ki.se
CHARLOTTE M. HÖÖG
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
OLLE BROSTRÖM
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
JÖRGEN GUSTAVSSON
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
MATS KARLSSON
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
PER MORITZ
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
ROBERT STIG
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
OLA WIKMAN
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
LARS MATTSSON
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
DOMENICO PALLI
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Background: The size of colorectal neoplastic polyps is important for their clinical management. Materials and Methods: The size of 12 polyp phantoms was assessed in tandem colonoscopies carried out by 7 endoscopists differing in years of clinical endoscopical experience. The endoscopists measured, with (n=5) or without (n=2) the aid of open forceps, the largest diameter of 12 polyp phantoms. Measurements in two independent trials were compared with the gold standard-size assessed at The Department of Production Engineering, The Royal Institute of Technology. Results: In tandem trials, 99.4% (167/168) of the measurements underscored the gold standard size. In the 1st trial, the size in all 84 measurements was underestimated by -40% (range -34% to -45%) and in the 2nd trial the size in 83 of the 84 measurements was underestimated by -34% (range -24% to -42%). Neither the age of the participant, nor the years of experience with clinical endoscopy improved the results obtained. The participants significantly underestimated larger devices (≥20 mm) whereas the smallest “polyps” were also underestimated, but with a lower degree of inaccuracy. The absolute difference between the golden standard size and the mean of all measurements performed on each polyp in 167 out of 168 measurements followed a regular downward trend. The volume of the devices was one of the confounding factors in size assessment. When compared to the gold standard size, the larger the “polyp” size, the higher the degree of underestimation. This may be crucial considering that the risk for colorectal adenomas to shelter an invasive growth is 46%, for adenomas measuring ≥2 cm, a limit accepted as a guideline worldwide for the management of patients with large colorectal polyps. Conclusion: Considering the clinical implications of the results obtained, the possibility of developing a method that would allow the assessment of the true size of polyps in clinical colonoscopy, is being explored.

  • Colonoscopy
  • polyps
  • size assessment

In 1887, Esmarch (1) pointed out that rectal adenomas could have a malignant potential. Forty years later, Feyter (2) confirmed these claims. Today it is generally understood that invasive carcinomas usually evolve from colorectal adenomas (3-13).

Thirty-five years ago it was demonstrated that the risk for colorectal adenomas to evolve into an invasive carcinoma correlated with the size of the lesion (3). In that classical work comprising 2506 colorectal adenomatous polyps, Muto et al. (3) found that the risk for adenomas measuring under 1 cm (largest diameter) to harbour an invasive carcinoma was 1%, for those measuring between 1 and 2 cm in diameter, the cancer risk increased to 10% and for those over 2 cm, to 46% . Pathologists worldwide (4-9) subsequently adopted these size limits as predictors of cancer risk and years later, these size limits were adopted by endoscopists (10-24).

To estimate the size of colorectal polyps, endoscopists often use as a reference, the distance between the opened blades of biopsy forceps. This method was applied to a large series of colorectal polyps (comprising 15989 polyps by the National Polyp Study Work Group (13,19), the Italian Multicentre Study Group (21), the Arizona Cancer Center Study (22), the South Korean Study Group (15) and more recently by Lieberman et al. (24). Patients were assigned groups based on the size of the poly(s) found at colonoscopy.

Using an artificial model, Margulies et al. (6) asked 6 gastroenterologists, 6 gastroenterology fellows and 7 untrained medical residents to measure ball bearings (3 mm to 19 mm) that were randomly inserted into a latex colon model. The size was estimated while being viewed with a video colonoscope, with and without the aid of an open biopsy forceps. It was found that the estimated size by the 19 participants were consistently lower (13% to 29%) than the actual size for all groups, with and without forceps. These results were confirmed by Fennerty et al. (23) who utilized an in vitro latex colon model with 13 steel balls (as polyps) of different sizes sewn into an artificial sigmoidoscopy-teaching model. Eight experienced endoscopists estimated the size of these 13 polyps in two separate sessions, two weeks apart and the results were compared to the “actual polyp size”, defined as the largest diameter of each polyp, measured by three independent observers with a conventional millimetre ruler. The average of the three measurements was taken as the “actual polyp size”. The result showed that the estimates of the size of the polyps by these experienced endoscopists were 35% lower than “the true polyp size” for all polyps and for all endoscopists in the two sessions (23).

In a recent study it was found that the measuring of polyp phantoms with a conventional millimetre ruler by 22 pathologists (25) resulted in disparate inter and intra-observer estimations, at variance with the gold standard size (GSS) assessed at The Royal Institute of Technology, Stockholm. That was the first work ever published in which the size of polyp phantoms, assessed with a conventional millimetre ruler, was controlled with measurements carried out at a technological University. It was found that using a conventional ruler (the tool of pathologists worldwide) unacceptably high intra-observer and inter-observer variations in assessing the size of “polyp”-phantoms occurred. In a more recent work (26), the size of the same 12 phantom polyps was assessed by Computed Tomography (CT) and compared to the GSS. Size-assessment by CT was more reliable than that obtained with a millimetre ruler since the disparate individual deviation-values found with the latter method were avoided. The volume and the shape of the devices influenced size assessment of phantom polyps by CT.

The aim of the present work was to record the size of artificially confectioned polyp phantoms in tandem colonoscopies calculated by 7 endoscopists. Their results were subsequently compared to the GSS previously assessed at The Royal Institute of Technology, Stockholm.

Materials and Methods

The polyp phantoms. Twelve artificial “polyps” were used. A core consisting of round or flat hard buttons of various sizes was wrapped with papier-mâché, painted with a colour and subsequently varnished (Figure 1). After drying they were placed in individual vials labelled #1 to #12.

Colonoscopic procedure. The test was carried out in one of the rooms of the Endoscopic Unit. In that room, one endoscopist at a time measured the 12 polyp phantoms. A polyp phantom to be measured, chosen at random, was introduced into a cylinder measuring 43 cm long and 6 cm in diameter provided with a lock at one of the free ends (Figure 2). An Olympus colonoscope (PC 160, Tokyo, Japan) was subsequently introduced into the cylinder carrying a polyp phantom (Figure 3).

Measurements of polyp phantoms done at the Endoscopical Unit, Department of Gastroenterology. The size given by the endoscopist was registered by one of us (CAR) in a chart carrying the number of the “polyps” from #1 to #12.

After completing that procedure for the 12 devices, a second examination was done (tandem colonoscopy), this time changing the order of the number of the polyp phantoms, also at random. The procedure was subsequently repeated with the waiting endoscopist isolated to avoid possible bias by overhearing the results obtained by a previous participant. Five endoscopists chose to measure the 12 devices with the aid of a forceps and the remaining two, without that aid. Participants were asked to give the size of the largest diameter of the polyp phantoms in whole millimetres.

Measurements of polyp phantoms done at The Royal Institute of Technology. The measurement of the 12 devices was done by low force contacting metrology, at a temperature of 20°C ± 1°C. Held between the finger tips, each artificial “polyp” was rotated in a gap of two parallel metal surfaces of a micrometer screw. The distance between the surfaces was reduced until the largest diameter of the polyp caused a slight friction when turned around in the gap. A measurement series was performed in random order among the 12 artificial devices. The micrometer screw (Mitutoyo Digimatic MDC-25MJT) has a certified uncertainty of 0.0016 mm. Only the “polyp” with the largest diameter was measured with a calliper, as its size exceeded the micrometer screw measurement range. The Luna calliper has 0.1 mm uncertainty. The procedure was repeated every second day and after 5 measurements, the average and standard deviations for each sample was calculated. It is worth noting that the contacting low friction technique applied in this study cannot be used for elastic or soft devices. Then non-contacting optical techniques would be preferred. The limitations of such a procedure are the high number of projections required to determine the maximum diameter.

Statistical analysis. To evaluate intra-individual reproducibility, the Concordance Correlation Coefficient (CCC) between the first and second measure was calculated for each endoscopist participating in the study. The Pearson's correlation coefficient (r) was also applied, to investigate the existence of a possible linear association between CCC and age, and between CCC and years of experience as endoscopist.

Each endoscopical measurement was compared to the absolute value provided by The Royal Institute of Technology (considered the gold standard size) and a percentage value was calculated. The mean of the percentages obtained in the 1st and the 2nd trials for each different pair endoscopist/polyp phantom was also calculated. In order to assess possible difference among the performances of the participants in the study, the Fisher's F-test was done to analyze variance.

Results

The size polyp phantoms assessed at The Royal Institute of Technology (gold standard size). The results are presented in Table I. The results show that the standard deviation for measurements of the largest diameter in the 12 devices was ≤0.05 mm when using the micrometer screw and ≤0.3 mm for the calliper. The difference in size in the 5 trials was non-significant.

Figure 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 1.

Twelve polyp phantoms used by 7 colonoscopists to assess the largest diameter in mm. The 12 polyp phantoms were subsequently measured at The Royal Institute of Technology, and the largest diameter obtained, in mm, was regarded as the gold standard size.

The size given by endoscopists in the 1st and 2nd colonoscopy trials. The seven endoscopists that carried out two non-consecutive measurements of 12 polyp phantoms provided a total of 168 measurements.

Age and years of clinical experience of colonoscopic examination: The mean age of the participants was 52 years (range: 38-62) and the mean years of experience in the field was 14 years (range: 2-30) (Table II).

Measurements. The results of all the measurements given in the 1st and the 2nd trials, are shown in Table III.

Colonoscopic trial # 1: Table IV shows that the “polyp” with the largest deviation (in mm) from the gold standard for all participants was “polyp” #3 (mean -9.23 mm), followed by “polyp” #4 (mean -7.97 mm) and the lowest deviation was recorded for “polyp” #5 (mean -3.41 mm) followed by “polyp” #1 (mean -3.66 mm). Table IV also shows that participant B had the highest mean deviation (-9.19 mm) whereas participant C had the lowest mean deviation (-4.69 mm). While participant B had 10 years of endoscopical experience with colonoscopy (Table II), participant C had only 5 years of endoscopical experience. Whereas participant A (-5.19 mm) had 30 years of of endoscopical experience (Table II), participant E (-6.27 mm) had only 2 years of colonoscopic training. Apparently, the years of colonoscopic experience were of no help in correctly assessing the size of polyps at endoscopic examination in trial # 1. Expectedly, the two participants who did not use forceps in calculating size (participants B and F (-9.19 mm and -7.02, with 10 and 23 years of experience, respectively) had the highest mean deviation (Table IV).

Figure 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 2.

Paraphernalia used to assess the size of polyp phantoms by 7 endoscopitsts.

Figure 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 3.

Colonoscopic view of a phantom polyp in the cylinder showing the open forceps used to calculate the size of the device.

Colonoscopic trial # 2: Table V shows that the device with the largest deviation from the gold standard was “polyp” #12 (mean -8.70 mm), followed by “polyp” #3 (mean -8.23 mm). The lowest deviation was recorded in “polyp” #5 (mean -1.98 mm) followed by “polyp” # 1 (mean -3.38 mm). Table V also shows that participant G (with 23 years of experience) recorded the highest mean deviation (-6.77 mm), whereas participants A and C (with 30 and 5 years of experience, respectively) recorded the lowest mean deviations (-4.02 mm and -4.02 mm, respectively). Even in trial # 2, the years of colonoscopic experience were of no help in the correct assessment of the size of polyps at endoscopic examination. For participants not using forceps in calculating size (participants B and F) the mean deviation from gold standard was high (-6.69 mm -6.36 mm, respectively in Table V) but also by participant G (-6.77 mm), who used the aperture of the forceps in calculating the size of the devices.

Comparing size obtained in trials #1 and # 2 to the gold standard size. Table VI shows that the largest calculated difference in size between the 1st and the 2nd trials was given by participant B, with 10 years of experience (-7.94 mm) and the lowest by participant C, with only 5 years of clinical colonoscopic experience (-4.36 mm).

Whereas participant E, with only 2 years of experience had a measuremet error of -5.69 mm between the 1st and the 2nd trials, participant G, with 23 years experience had an error of -6.06 between the 1st and the 2nd trials. Apparently the years of colononoscopic experience were of no help in reducing errors in the readings of the size of the devices in tandem trials. Table VII shows the poor overall concordance correlation coefficient (CCC) between the 1st and the 2nd trials. The intra-individual reproducibility indicated that only one CC value was lower than 0.70.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table I.

The size, in 12 polyp phantoms.

The Pearson's r coefficients for the linear association between CC and age or years of experience as endoscopist resulted in non-significantly differences from the null value (not shown). The analysis of variance showed a significantly greater inter-individual reproducibility than the intra-individual one, with a F-test value of 11.54 (p<0.001).

Discussion

The results of this investigation demonstrated that 99.4% or 167 of a total of 168 measurements done by the 7 endoscopists in two tandem trials underscored the gold standard values. In the 1st trial, all 84 measurements underestimated the gold standard size by -40% (range -34% to -45%). In the 2nd trial, 83 of the 84 measurements underestimated the gold standard size by -34% (range -24% to -42%). Thus, the absolute difference between the golden standard size and the mean of all measurements performed on each polyp in 167 of 168 measurements followed a regular downward trend. The cause(s) responsible for the overall underestimation of the size of polyp phantoms by virtual colonoscopy in tandem trials remain elusive. Neither the age of the observer, nor the years of experience with clinical endoscopy improved the results obtained.

Some of the confounding factors that could help to explain the failure of endoscopists to adequately measure colorectal polyps may be: a) that endoscopists do not re-check their own initial polyp size with a second measurement, b) that endoscopists do not double-check the size obtained with another endoscopist, before the polyp is excised, c) that the distance between opened biopsy forceps used in colonoscopies may differ, when different forceps are used (for some 6 mm apart (23) and for others 8 mm apart (17), and d) that the blades of the forceps failed to open-wide, thus interfering with the calculation of the size of the polyp while extrapolating that aperture. Another, not previously envisaged confounding factor that might explain the failure of measuring polyps at endoscopy, is the large bulk of the polyp. In fact, “polyps” #3 and # 12 were the largest (see Figure 1) and were the ones that were underscored with the largest deviation from gold standard by all participants. Participants significantly underestimated the larger devices, whereas the smallest “polyps” were also underestimated but with a lower degree of inaccuracy. Thus, the results of this work seem to suggest that when measuring polyps through a colonoscope, the larger the “polyp” size, the higher the degree of underestimation when compared to the gold standard size. This may be crucial considering that the risk for colorectal adenomas (histologically proven) measuring ≥2 cm, to shelter an invasive growth is 46% (3). That limit has been accepted worldwide as a guideline for the management of patients with “large” colorectal polyps.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table II.

The age of the endoscopists participating in the study and the years of colonscopic experience.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table III.

Results of the two measurement (in mm) of 12 polyp phantoms done by the seven endoscopists participating to the study.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table IV.

Deviation (compared to golden standard) of measurements (in mm) of 12 polyp phantoms given by 7 endoscopists participating in the study - 1st trial.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table V.

Deviation (compared to golden standard) of measurements (in mm) of 12 polyp phantoms given by 7 endoscopists participating in the study - 2nd trial.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table VI.

Deviation (compared to golden standard) of measurements (in mm) of 12 polyp phantoms given by 7 endoscopists participating in the study - Mean of 1st and 2nd trial.

In daily praxis, endocopists assess the size of colorectal polyps before removal, usually by comparing the aperture of the blades of the forceps and extrapolating that size to larger polyps, a method that was used here by 5 of the 7 participants. In the 1st trial, the two endoscopists that disregarded the aperture of the forceps in calculating the size of the “polyps”, recorded the highest underestimation size but in the 2nd trial the highest underestimation size was given by a endoscopist G with 23 years of clinical endoscopic experience, who used the aperture of the forceps to measure the devices. Thus, in the 2nd trial, the underscoring of the size of the “polyps” was not improved by the aid of the aperture of the forceps. The results obtained seem to substantiate the recent statement of Rex and Goldblum, namely that “colonoscopy is not perfect” (27).

In sum, the method of calculating “polyps” size by endoscopic examination as used in the present work, proved to be unreliable. And yet, the size of colorectal polyps given at “first glance” by the clinical endoscopist on duty is usually transferred to hospital records, results that subsequently are used in clinical publication concerning polyps at risk. Moreover, endoscopists together with pathologists, radiologists and gastroenterologists usually discuss at clinical conferences the strategy to be applied in the management of colonic polyps measuring 2 cm or more in diameter.

It should be understood that in clinical praxis, the work of endoscopists is very complex; they must focus not only on the needs of the patient during the examination, but also in the technical requirements, in the characteristics both of the colorectal mucosa as well as of the newly detected polyp (surface structure, colour, size and photographical documentation) before the polyp is removed with a forceps for subsequent histological evaluation at the Department of Pathology. Thus, in clinical praxis, size estimation is only one of several steps in the endoscopical examination of patients with newly detected colorectal polyps. This circumstance contrasts with that of the present work, in which the participants were only focused on the measuring of the devices through the colonoscope.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table VII.

Concordance correlation coefficients (CCC) and 95% confidence intervals (95% CI) for the agreement between the mean of 1st and 2nd trial and gold standard value for the seven endoscopists participating in the study.

A method to improve the assessment of the size of endoscopically removed polyps is being developed (28). Alternative methods that would permit a better assessment of the size of clinical polyps before excision, that is at colonoscopical examination, should be explored.

Acknowledgements

Thanks are due to Dr. Saverio Caini, ISPO, Florence, for technical assistance.

  • Received October 8, 2008.
  • Revision received January 7, 2009.
  • Accepted February 12, 2009.
  • Copyright© 2009 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved

References

  1. ↵
    1. Esmarch F
    : Die Krankheiten des Mastdarmes und desAfters. Deutsche Chirurgie Bd 48 Stuttgart, 1887.
  2. ↵
    1. Feyter F
    : Zur Geschwulstlehre (nach Untersuchungen am menschichlen Darm): Polypen und Krebs. Beitr Pathol Anat 86: 663-759, 1931.
    OpenUrl
  3. ↵
    1. Muto T,
    2. Bussey HJ,
    3. Morson BC
    : The evolution of cancer of the colon and rectum. Cancer 36: 2251-2270, 1975.
    OpenUrlCrossRefPubMed
  4. ↵
    1. Cooper HS
    : Surgical pathology of endoscopically removed malignant polyps of the colon and rectum. Am J Surg Pathol 7: 613-623, 1983.
    OpenUrlPubMed
    1. Schoen RE,
    2. Gerber LD,
    3. Margulies C
    : The pathologic measurement of polyp size is preferable to the endoscopic estimate. Gastrointest Endosc 46: 492-496, 1997.
    OpenUrlCrossRefPubMed
  5. ↵
    1. Aldridge AJ,
    2. Simson JN
    : Histological assessment of colorectal adenomas by size. Are polyps less than 10 mm in size clinically important? Eur J Surg 7: 777-779, 2001.
    OpenUrl
    1. Fong TV,
    2. Chuah SK,
    3. Chiou SS,
    4. Chiu KW,
    5. Hsu CC,
    6. Chiu YC,
    7. Wu KL,
    8. Chou YP,
    9. Ong GY,
    10. Changchien CS
    : Correlation of the morphology and size of colonic polyps with their histology. Chang Gung Med J 26: 339-343, 2003.
    OpenUrlPubMed
    1. Hoff G,
    2. Clausen OP,
    3. Fjordvang H,
    4. Norheim A,
    5. Foerster A,
    6. Vatn MH
    : Epidemiology of polyps in the rectum and sigmoid colon. Size, enzyme levels, DNA distributions, and nuclear diameter in polyps of the large intestine. Scand J Gastroenterol 20: 983-989, 1985.
    OpenUrlPubMed
  6. ↵
    1. Rubio CA,
    2. Nesi G,
    3. Messerini L,
    4. Zampi G
    : Serrated and microtubular colorectal adenomas in Italian patients. A 5-year survey. Anticancer Res 25: 1353-1359, 2005.
    OpenUrlAbstract/FREE Full Text
  7. ↵
    1. Hoff G,
    2. Vatn M
    : Endoscopic evaluation of size and localization of polyps. Scand J Gastroenterol 20: 356-360, 1985.
    OpenUrlPubMed
    1. Gopalswamy N,
    2. Shenoy VN,
    3. Choudhry U,
    4. Markert RJ,
    5. Peace N,
    6. Bhutani MS,
    7. Barde CJ
    : Is in vivo measurement of size of polyps during colonoscopy accurate? Gastrointest Endosc 46: 497-502, 1997.
    OpenUrlCrossRefPubMed
    1. Noshirwani KC,
    2. van Stolk RU,
    3. Rybicki LA,
    4. Beck GJ
    : Adenoma size and number are predictive of adenoma recurrence: implications for surveillance colonoscopy. Gastrointest Endosc 51: 433-437, 2000.
    OpenUrlCrossRefPubMed
  8. ↵
    1. Winawer SJ,
    2. Stewart ET,
    3. Zauber AG,
    4. Bond JH,
    5. Ansel H,
    6. Waye JD,
    7. Hall D,
    8. Hamlin JA,
    9. Schapiro M,
    10. O'Brien MJ,
    11. Sternberg SS,
    12. Gottlieb LS
    : A comparison of colonoscopy and double contrast barium enema for surveillance after polypectomy. National Polyp Study Work Group N Engl J Med 342: 1766-1772, 2000.
    OpenUrlCrossRefPubMed
    1. Punwani S,
    2. Halligan S,
    3. Irving P,
    4. Bloom S,
    5. Bungay A,
    6. Greenhalgh R,
    7. Godbold J,
    8. Taylor SA,
    9. Altman DG
    : Measurement of colonic polyps by radiologists and endoscopists: who is most accurate? Eur Radiol 18: 874-881, 2008.
    OpenUrlCrossRefPubMed
  9. ↵
    1. Park DH,
    2. Kim HS,
    3. Kim WH,
    4. Kim TI,
    5. Kim YH,
    6. Park DI,
    7. Kim HJ,
    8. Yang SK,
    9. Byeon JS,
    10. Lee MS,
    11. Chung IK,
    12. Jung SA,
    13. Jeen YT,
    14. Choi JH,
    15. Choi H,
    16. Han DS
    : Clinicopathologic characteristics and malignant potential of colorectal flat neoplasia compared with that of polypoid neoplasia. Dis Colon Rectum 51: 43-49, 2008.
    OpenUrlPubMed
    1. Margulies C,
    2. Krevsky B,
    3. Catalano MF
    : How accurate are endoscopic estimates of size? Gastrointest Endosc 40: 174-177, 1994.
    OpenUrlPubMed
  10. ↵
    1. Morales TG,
    2. Sampliner RE,
    3. Garewal HS,
    4. Fennerty MB,
    5. Aickin M
    : The difference in colon polyp size before and after removal. Gastrointest Endosc 43: 25-28, 1996.
    OpenUrlCrossRefPubMed
    1. O'Brien MJ,
    2. Winawer SJ,
    3. Zauber AG,
    4. Gottlieb LS,
    5. Sternberg SS,
    6. Diaz B,
    7. Dickersin GR,
    8. Ewing S,
    9. Geller S,
    10. Kasimian D,
    11. Komorowski R,
    12. Spzporn A,
    13. The National Polyp Study
    : Patient and polyp characteristics associated with high-grade dysplasia in colorectal adenomas. Gastroenterology 98: 371-379, 1990.
    OpenUrlPubMed
  11. ↵
    1. Winawer SJ,
    2. Zauber AG,
    3. Fletcher RH,
    4. Stillman JS,
    5. O'Brien MJ,
    6. Levin B,
    7. Smith RA,
    8. Lieberman DA,
    9. Burt RW,
    10. Levin TR,
    11. Bond JH,
    12. Brooks D,
    13. Byers T,
    14. Hyman N,
    15. Kirk L,
    16. Thorson A,
    17. Simmang C,
    18. Johnson D,
    19. Rex DK,
    20. US Multi-Society Task Force on Colorectal Cancer
    . Guidelines for colonoscopy surveillance after polypectomy: a consensus update by the US Multi-Society Task Force on Colorectal Cancer and the American Cancer Society. Gastroenterology 130: 1872-1885, 2006.
    OpenUrlCrossRefPubMed
    1. Riner MA,
    2. Rankin RA,
    3. Guild RT 3rd.,
    4. Kastens DJ
    : Accuracy of estimation of colon polyp size. Gastrointest Endosc 34: 284-288, 1988.
    OpenUrlPubMed
  12. ↵
    1. Martinez ME,
    2. Sampliner R,
    3. Marshall JR,
    4. Bhattacharyya AK,
    5. Reid ME,
    6. Alberts DS
    : Adenoma characteristics as risk factors for recurrence of advanced adenomas. Gastroenterology 120: 1077-1083, 2001.
    OpenUrlCrossRefPubMed
  13. ↵
    1. Citarda F,
    2. Tomaselli G,
    3. Capocaccia R,
    4. Barcherini S,
    5. Crespi M
    : The Italian Multicentre Study Group. Efficacy in standard clinical practice of colonoscopic polypectomy in reducing colorectal cancer incidence. Gut 48: 812-815, 2001.
    OpenUrlAbstract/FREE Full Text
  14. ↵
    1. Fennerty MB,
    2. Davidson J,
    3. Emerson SS,
    4. Sampliner RE,
    5. Hixson LJ,
    6. Garewal HS
    : Are endoscopic measurements of colonic polyps reliable? Am J Gastroenterol 88: 496-500, 1993.
    OpenUrlPubMed
  15. ↵
    1. Lieberman D,
    2. Moravec M,
    3. Holub J,
    4. Michaels L,
    5. Eisen G
    : Polyp Size and Advanced Histology in Patients Undergoing Colonoscopy Screening: Implications for CT Colonography. Gastroenterology. 2008 Jul 3 [Epub ahead of print] PMID: 18691580 [PubMed - as supplied by publisher].
  16. ↵
    1. Rubio CA,
    2. Grimelius L,
    3. Lindholm J,
    4. Hamberg H,
    5. Porwit A,
    6. Elmberger G,
    7. Höög A,
    8. Kanter L,
    9. Eriksson E,
    10. Stemme S,
    11. Orrego A,
    12. Saft L,
    13. Petersson F,
    14. De La Torre M,
    15. Ekström C,
    16. Astrom K,
    17. Rundgren A,
    18. Djokic M,
    19. Chandanos E,
    20. Lenander C,
    21. Machado M,
    22. Nilsson P,
    23. Mattsson
    : Reliability of the reported size of removed colorectal polyps. Anticancer Res 26: 4895-4899, 2006.
    OpenUrlAbstract/FREE Full Text
  17. ↵
    1. Suzuki C,
    2. Matsson L,
    3. Rubio CA
    : Assessing polyp size by improved digitalized computed tomography (CT). Anticancer Res 28: 1911-1915, 2008.
    OpenUrlAbstract/FREE Full Text
  18. ↵
    1. Rex DK,
    2. Goldblum JR
    : Villous elements and high-grade dysplasia help guide post-polypectomy colonoscopic surveillance. Am J Gastroenterol 103: 1327-1329, 2008
    OpenUrlPubMed
  19. ↵
    1. Rubio CA
    : A single method to document the size of endoscopically-excised colorectal polyps. In Vivo 21: 1103-1106, 2007.
    OpenUrlAbstract/FREE Full Text
PreviousNext
Back to top

In this issue

Anticancer Research
Vol. 29, Issue 5
May 2009
  • Table of Contents
  • Table of Contents (PDF)
  • Index by author
  • Front Matter (PDF)
  • Back Matter (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Anticancer Research.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Assessing the Size of Polyp Phantoms in Tandem Colonoscopies
(Your Name) has sent you a message from Anticancer Research
(Your Name) thought you would like to see the Anticancer Research web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
5 + 9 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Assessing the Size of Polyp Phantoms in Tandem Colonoscopies
CARLOS A. RUBIO, CHARLOTTE M. HÖÖG, OLLE BROSTRÖM, JÖRGEN GUSTAVSSON, MATS KARLSSON, PER MORITZ, ROBERT STIG, OLA WIKMAN, LARS MATTSSON, DOMENICO PALLI
Anticancer Research May 2009, 29 (5) 1539-1545;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Reprints and Permissions
Share
Assessing the Size of Polyp Phantoms in Tandem Colonoscopies
CARLOS A. RUBIO, CHARLOTTE M. HÖÖG, OLLE BROSTRÖM, JÖRGEN GUSTAVSSON, MATS KARLSSON, PER MORITZ, ROBERT STIG, OLA WIKMAN, LARS MATTSSON, DOMENICO PALLI
Anticancer Research May 2009, 29 (5) 1539-1545;
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Materials and Methods
    • Results
    • Discussion
    • Acknowledgements
    • References
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

Cited By...

  • CD204-Positive Tumor-associated Macrophages Relate to Malignant Transformation of Colorectal Adenoma
  • p53 Up-regulation During Colorectal Carcinogenesis
  • Pitfall in Assessing the Size of Tumor Phantoms on Mammograms
  • The Size of Colon Polyps Revisited: Intra- and Inter-observer Variations
  • Google Scholar

More in this TOC Section

  • Tolerance and Outcomes of Partial Breast Radiation in a Community-based Setting
  • Effectiveness of Pembrolizumab Monotherapy for Older Adults With Head and Neck Carcinoma by CPS Status
  • Diuretic Administration for Vomiting During Concurrent Chemoradiotherapy for Cervical Cancer: A Multicenter Retrospective Study
Show more Clinical Studies
Anticancer Research

© 2026 Anticancer Research

Powered by HighWire